(1. 3) Changing each setting in E.TRG mode
The E.TRG has five modes; 1P SNR, 1P SR, PW SNR, PW SR, RR.
First set the "→" to MODE and select E. TRG, then set the "→" to E.TRG and select the desired E.TRG mode.
(1. 3. 1) Changing each setting in 1P SNR mode
Move up down |
|
| Set by pushing | |||||
By pushing |
|
| ||||||
|
| DATA UP, DOWN | ||||||
MENU UP, DOWN |
|
| ||||||
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
MODE | E.TRG | |||
E.TRG | 1P SNR | |||
TRG.P |
|
|
|
|
|
|
|
| |
EXP. | 16ms | |||
PART | OFF |
<MODE = E.TRG E.TRG = 1P SNR>
•Shutter mode MANU, SS, E.TRG
•E.TRG mode
1P SNR, 1P SR, PW SNR, PW SR, RR
•Input trigger pulse setting at 1P SNR and 1P SR
Input trigger pulse : positive polarity Input trigger pulse : negative polarity
•Exposure time setting at 1P SNR and 1P SR
0.01 ms |
| 0.02 ms |
| 0.4 ms |
| 1 ms |
|
| 16 ms | ||
|
|
|
| ||||||||
0.01 ms | 0.02 ms | 0.1 ms | 1 ms | ||||||||
step | step | step | step |
•Partial scanning switch OFF/60fps/90fps/E.60fps/E.90fps
(a) Changing the polarity of inputting trigger pulse setting
1Set the "→" to TRG.P by pushing [MENU UP], [MENU DOWN] buttons.
2Select either , by pushing [DATA UP], [DATA DOWN] buttons.
(b) Changing 1P SNR exposure time setting
1Set the "→" to EXP. by pushing [MENU UP], [MENU DOWN] buttons.
2Set the exposure time by pushing [DATA UP], [DATA DOWN] buttons.
Note:
The longer the storage time with extended exposures, the more visible certain characteristics of CCD cameras become: fixed pattern noise, white pixels, etc.
(c) Changing the partial scanning setting
1Set the "→" to PART by pushing [MENU UP], [MENU DOWN] buttons.
2Select either OFF/60fps/90fps/E.60fps/E.90fps by pushing [DATA UP], [DATA DOWN] buttons.