(3. 2) Pulse Width Trigger
Trigger*1
About 1 ∝s | About 7 ∝s | ||
|
|
|
|
Exposure period*2
(Internal VD)*3
RGB data (video interval image)
FVAL
LVAL,
DVAL
28H (Partial scanning OFF)
38H (Partial scanning 60fps)
47H (Partial scanning 90fps)
Negative polarity mode
Positive polarity mode
Exposure period*2
*1: Externally input signal
*2: Exposure time = Trigger pulse width + 6 ∝s
(Valid trigger pulse width is 2 ∝s or greater for external trigger shutter operation.)
*3: As long as there is no external sync input, the internal VD will be output when SJ01 is set to HD/VD output position.
*4: Video is output at the falling edge of the internal VD following completion of the exposure period. The video and FVAL/LVAL/DVAL have a paired relationship.
Note:
When the next trigger is input before completion of the output of the video corresponding to the trig- ger, there will be an effect on the video.
28