Connection
Connecting to connection |
|
| ||
External Control Connector |
| GND | ||
|
|
| MD | |
|
|
| COM | |
|
|
| FOCUS | |
|
|
| ZOOM | |
Connector | Function | Signal Level | I/O | |
| Tele | +6V~+12V |
| |
ZOOM | COM | I | ||
| ||||
|
| |||
| Wide | COM |
| |
|
| |||
|
|
| ||
| Far | +6V~+12V |
| |
FOCUS | COM | I | ||
|
| |||
| Near | COM |
| |
|
| |||
COM |
| COM | - | |
|
| +4.0V~+5.0V |
| |
MD |
| There is motion | O | |
0V | 5±0.5sec | |||
| There is no motion |
|
|
*MD (Motion Detection) Output Signal Level (less than 10mA)
*When using the MD function, the 'GND' should be connected to the frame ground.
Communication Control Connector
The camera can be controlled by using external controllers like a Remote controller.
Remote Controller | ||
| Cable |
* Communication Control Connector Pin Description .
Number | Name | Description | Number | Name | Description |
|
|
|
|
|
|
1 | GND | - | 4 | TRX + | |
|
|
|
|
|
|
2 | EXT.SYNC | External ‘SYNC’ Signal | 5 | TRX - | |
|
|
|
|
|
|
3 | GND | - | 6 | Output Power | Remote Controller only |
|
|
|
|
|
|
* EXT. SYNC |
| 3V or 5V |
| Min: 500ns | 0V |
|
| |
| 60Hz ± 0.1Hz(NTSC), 50Hz ± 0.1Hz(PAL) |
*Communication Setting can set the communication setting as shown in the table below. When you use to connect
ITEM |
|
|
MODE | Serial | Serial |
Data Bit | 8 bit | 8 bit |
Bit/Sec | 9600bps | 9600bps |
Parity | EVEN | NONE |
CAM ID NO. | 0 | 1~255 |
RETURN PACKET | ENABLE | See the |
|
|
|
Notes
• Contact an authorized technician for inspection.
COLOR CCD CAMERA 16 User’s Manual | COLOR CCD CAMERA 17 User’s Manual |