Samsung A6 installation manual Outdoor Unit

Page 25

ENGLISH

 

MODEL

 

AS18✴✴RC

AS24✴✴RC

 

 

 

 

 

 

 

 

 

Performance

Capacity Cooling

 

Btu/h

17500

23500

 

Ratings

 

 

 

 

 

 

 

 

 

SEER

 

 

10.0

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Moisture Removal

 

Pts/h

4.2

5.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air FLOW(Cooling, HIGH)

 

CFM

477

477

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sound Rating-Outdoor

 

dB

55

59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

Power source

 

 

208-230V~, 60Hz

208-230V~, 60Hz

Data

 

 

 

 

 

 

 

 

 

Min.Ampacity

 

A

8.6

10.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Watts

 

W

1900

2350

 

 

 

 

 

 

 

 

 

 

 

 

Refrigeration

Connections

 

 

Flare

Flare

 

Lines

 

 

 

 

 

 

 

 

 

Liquid Line O. D.

 

mm(in)

6.35(1/4)

6.35(1/4)

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction Line O.D.

 

mm(in)

12.70(1/2)

15.88(5/8)

 

 

 

 

 

 

 

 

 

 

 

Factory Pre-charge

 

m(ft)

5.0 ( 1621 )

5.0 ( 1621 )

 

 

 

 

 

 

 

 

 

 

 

Max. Line length

 

m(ft)

15.0 ( 4941 )

20.0 ( 65

1

)

 

 

2

 

 

 

 

 

 

 

 

 

 

 

Max. Height Difference

 

m(ft)

7.0(23)

8.0 ( 26

1

 

)

 

 

4

 

 

 

 

 

 

 

 

 

 

Dimensions

INDOOR UNIT

 

AS18✴✴RC

AS24✴✴RC

& Weight

 

 

 

 

 

 

 

 

 

W X H X D

 

mm(in)

1080 x 275 x 204

1080 x 275 x 204

 

 

 

 

( 42 12 x 11 x 8 )

( 42 12 x 11 x 8 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight

 

Ibs

29.7

29.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR UNIT

 

US18✴✴RC

✴✴

RC

 

 

 

US24

 

W X H X D

 

mm(in)

880 x 638 x 310

880 x 638 x 310

 

 

( 3421 x 2581 x 12 14 )

( 3421 x 2581 x 12 14 )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight

 

Ibs

105.8

138.9

 

 

 

 

 

 

 

 

 

 

 

 

E-25

Image 25
Contents Installation Manual Manual DE Instrucciones Safety Precautions Contents Indoor Unit View of the UnitOutdoor Unit Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Selecting with the Remote Control Using with the indoor unitWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyTo Cancel the On Timer Setting the On TimerTo Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsMode Outdoor Temperature Indoor Temperature Indoor Humidity Temperature and Humidity RangesIf the air conditioner is used at... Then Model AS07A5A6MA / AS09A5A6MA / AS12A5A6MC Cleaning Your Air ConditionerAUTO, Cool Solving Common ProblemsInstalling a Filter Option Model Technical SpecificationsOutdoor Unit Installation Manual Electrical Work Indoor Unit Deciding on Where to Install the Air Conditioner30mm1inch or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesAccessories in the Outdoor Unit Case Then follow Steps Fixing the Installation PlatePurging the Unit Connecting the Assembly Cable07/09/12 To install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingTorque Depth a Cutting/Extending the Piping07/09 Connecting the Cables to the Outdoor Unit18/24 Electrical Work Auxiliary Circuit Breaker5019 Checking Correct EarthingFixing the Unit in Position If you have used Then Connecting Up and Purging the CircuitPerforming Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics