INSTALLING THE OUTDOOR UNIT

Connecting the Cables to the Outdoor Unit

One electric cable must be connected to the outdoor unit:

The assembly cable connecting the indoor unit to the outdoor unit

1Remove the terminal board cover on the side of the outdoor unit.

2Connect the assembly cable to terminals as shown in the figure.

Each wire is labelled with the corresponding terminal number.

3Connect the earth wires to the earth terminals.

Refer to the page 39 for further details on how to check that earthing is correct.

4Replace the terminal board cover, carefully tightening the screw.

ENGLISH

✴✴07/09✴✴

✴✴12✴✴

✴✴18/24✴✴

✴✴07/09/12✴✴

Indoor unit N1 1

2

3

N

L

E

 

1

 

 

N

L E

Outdoor unit N

L

1

 

 

E

N

L

1

2

3

 

N

L

E

 

Earth terminal

✴✴18✴✴

Indoor unit N1

L1

1

2 3

4

E

 

N1

L1

1

2

 

E

Outdoor unit N1

L1

1

2

 

E

N1 L1 1 2 3 4 N L

Earth

N L E terminal

✴✴24✴✴

Indoor unit N1

L1

1

2

3

4

E

 

N1

L1

1

2

3

 

E

Outdoor unit N1

L1

1

2

3

 

E

N1 L1 1 2 3 4 N L

Earth

N L E terminal

Circuit Breaker(Main Power)

Circuit Breaker(Main Power)

Circuit Breaker(Main Power)

E-37

Image 37
Contents Installation Manual Manual DE Instrucciones Safety Precautions Contents Indoor Unit View of the UnitOutdoor Unit Remote Control Buttons and Display Getting Started Inserting the Remote Control Batteries Selecting with the Remote Control Using with the indoor unitWay Function To obtain anSelecting the Automatic Operating Mode Cooling Your Room Changing the Room Temperature Quickly Removing Excess Humidity Airing Your Room Adjusting the Air Flow Direction Horizontally Adjusting the Air Flow Direction VerticallyTo Cancel the On Timer Setting the On TimerTo Cancel the Off Timer Setting the Off TimerTo Cancel the Sleep Timer Setting the Sleep TimerTopic Recommendation Operating RecommendationsMode Outdoor Temperature Indoor Temperature Indoor Humidity Temperature and Humidity RangesIf the air conditioner is used at... Then Model AS07A5A6MA / AS09A5A6MA / AS12A5A6MC Cleaning Your Air ConditionerAUTO, Cool Solving Common ProblemsInstalling a Filter Option Model Technical SpecificationsOutdoor Unit Installation Manual Electrical Work Indoor Unit Deciding on Where to Install the Air Conditioner30mm1inch or more Accessories in the Indoor Unit Case Air Conditioner and AccessoriesAccessories in the Outdoor Unit Case Then follow Steps Fixing the Installation PlatePurging the Unit Connecting the Assembly Cable07/09/12 To install the drain hose, proceed as follows Installing and Connecting the Indoor Unit Drain HosePipe Installing and Connecting the Indoor Unit Assembly PipingTorque Depth a Cutting/Extending the Piping07/09 Connecting the Cables to the Outdoor Unit18/24 Electrical Work Auxiliary Circuit Breaker5019 Checking Correct EarthingFixing the Unit in Position If you have used Then Connecting Up and Purging the CircuitPerforming Leak Tests To check for gas leaks on Then, using a leak detector CheckPlacing the Indoor Unit in Position Checking and Testing Operations Explaining Operations to the Owner Electronics