Installation
Top of Form (TOF) Sensor
Calibrating the TOF Sensor
1.Open the printhead.
2.Remove ticket stock.
3.Press and hold the Feed button, and then close the printhead (keeping the button pressed all the time).
4.Release the button.
The Status LED should be off.
5.Load ticket stock (slide it into the paper guide and let the printer auto load the paper).
Note • To ensure good calibration conditions, lightly press the ticket stock towards the bottom of the input guide during calibration.
The printer will forward the paper until it finds two TOF marks and then stop and save all
6.Open the printhead and remove the ticket stock.
7.Close the printhead and feed the tickets in through the paper guide again. The printer is ready for use.
Repeat this procedure if the calibration fails or if the printer is used with tickets that differ from the original specification.