Installation
Installing a Paper Guide
9.Select Parameter 63 (BM Sensor) and enter the desired value. Recommended values are:
Value | When Used |
|
|
0 | Auto selects 1 or 4 based on width of media loaded |
|
|
1 | (edge sensor) for ATB tickets without hole in the perforation. |
|
|
2 | (center sensor) for ISO tickets, most other ticket types, and adhesive labels |
|
|
3 | 17.5 mm from center sensor |
|
|
4 | 12.5 mm from center sensor (for baggage tags according to IATA 740) |
|
|
10.Select Upload One.
11.Select Store Values to Flash PROM.
12.Wait for the printer to buzz as a confirmation that the new value is stored.
15
11/04/2009 | TTP 2100 Operator Guide |