INTRODUCTION
Controls, Connectors and Indicators (Continued)
13 | [ | , | , | , | ] |
| right Button |
| |||
| These buttons select items on the menu | ||||
| screen and change a set value. | ||||
| ( Page 23) |
|
14 | |
| Switch of External Synchronization |
| Signal |
| This is a terminating ON/OFF switch for |
| the external synchronization input signal. |
| When this is switched ON, termination is |
| executed via a 75 Ω resistor. |
| ON: terminates at 75Ω. |
| OFF: does not terminate at 75Ω. |
| (ON: At time of factory shipment) |
15 | [INT/GL, LL] Selector Switch for |
SIMPLEX: This switch sets to SIMPLEX when the transmission between the camera and a remote control unit is in a simplex system
17 | |
| ON/OFF Switch |
| This sets whether or not the signal |
| between RX + and RX – on the back 20 |
| should be terminated at the value of |
| 110Ω resistance. |
| ON: terminates. |
| OFF: does not terminate. |
| If the system including the camera is the |
| M.DROP |
| only the camera mounted at the terminal |
| ( |
|
| ) |
| ⁄ | |
|
| + | - |
|
|
|
|
|
| 1 | 2 |
|
|
|
|
DC12V | AC24V |
| CLASS 2 ONLY(U TYPE) | TX+ TX- RX+ RX- AUX GND | |||
| ISOLATEDPOWERONLY TYPE)(E | B | C | D | |||
|
|
|
| A | |||
fi |
|
|
|
|
|
| Y/C OUT |
| SYNC IN | VIDEO OUT |
|
|
| ||
› |
|
|
|
|
|
| SEE INST- |
| POWER |
|
|
|
| RUCTION | |
|
|
|
|
| MANUAL | ||
‹ | |||||||
|
|
fl
| TX+ TX- RX+ RX- AUX GND |
| A B C D |
| Y/C OUT |
¤ |
|
SYNC IN | VIDEO OUT |
| SEE INST- |
| RUCTION |
POWER | MANUAL |
| |
|
| Synchronizing System |
|
| This switch can set a synchronizing system | |
| of the camera. |
|
| INT/GL: |
|
| This is set for internal synchronization | |
| (INT) or external synchronization (GL). | |
| LL (Line Lock): |
|
| The camera’s vertical synchronization is | |
| locked to the AC 24V power line frequency. | |
| When switching between multiple cameras | |
| using a switcher, selecting this mode and | |
| adjusting the vertical phase can reduce the | |
| monitor sync disturbances occurring when | |
| the camera image is switched. (This cannot | |
| be used in regions where the power | |
| frequency is 60 Hz (50 Hz ( | |
| (INT/GL: At time of factory shipment) | |
16 | [DUPLEX, SIMPLEX] Selector Switch | |
| for Transmission System |
|
| If the setting is changed, be absolutely | |
| sure to switch on the power again. | |
| DUPLEX: |
|
| This switch sets to DUPLEX when the | |
| transmission between the camera and a | |
| remote control unit is in a duplex system | |
|
|
| of control signal cable is set to “ON” and |
| the other camera is set to “OFF”. In case |
| of the M.DROP system, it becomes |
| necessary to set the Machine ID. ( Page |
| 33) |
| If the system including the camera is the |
| P TO P (Point to Point, |
| set this switch of all the cameras to “ON”. |
| The item STYLE on the COMMUNICA- |
| TION screen sets M.DROP or P TO P |
| ( Page 33) |
| (ON: At time of factory shipment) |
18 | NOT USED |
| This cannot be used. Do not switch. |
19 | [DC 12V, AC 24V] Power input terminals |
| |
| To input DC 12V or AC 24V power. |
20 | [TX+A, |
| signal connection terminals |
| Terminals for inputting signals with |
| electrical characteristics conforming to |
| the EIA/TIA |
| 17 RX.TERM switch |
21 | [AUX, GND] Auxiliary OutputTerminals |
| If any change occurs in the area that was |
| set on the MOTION DETECT screen, these |
| terminals output signals. ( Page 31) |
| |
| voltage 30V, Current 30mA.] |
22 | [Y/C OUT] Y/C output connector |
| This |
| and chrominance signal. |
| • Pin configuration of Y/C OUT connector |
4 | 3 |
2 | 1 |
Pin No. | Signal |
1GND
2GND
3Luminance (Y)
4Chrominance (C)
23 | [VIDEO OUT] Video signal output |
| connector |
| This BNC connector outputs a composite |
| video signal. Connect this to the video input |
| connector of a video monitor, switcher, etc. |
24 | [POWER] Power indicator lamp |
| This lamp lights when power is supplied |
| to the camera. |
25 | [SYNC IN] Sync signal input connector |
| This BNC connector accepts the input of |
| an external sync signal such as a composite |
| video (VBS) or black burst (BB) signal. |
| When a sync signal is input into this |
| connector, the camera operation is |
| automatically synchronized with the |
| external sync signal. |
| To terminate this connector at 75Ω, turn |
| ON the EXT.TERM switch 14 . |
26 | Power cable |
| Connect to the commercial AC230V |
| outlet |