CONNECTION/INSTALLATION
Connections on the back
Power supply
TK-C1480U and TK-C1480E (DC 12 V or 24 V)
| + | - |
| 1 | 2 |
DC12V | AC24V | CLASS2 ONLY(U TYPE) ISOLATEDPOWER ONLY (E TYPE) |
|
| TX+ TX- RX+ RX- AUX GND |
|
| A B C D |
|
| Y/C OUT |
| SYNC IN | VIDEO OUT |
|
| SEE INST- |
| POWER | RUCTION |
| MANUAL |
Connect the DC 12 V or the AC 24 V power | |||||
supply to the DC 12V/AC 24V terminals. To | |||||
prevent connection errors or a | cable | ||||
disconnection, we recommend the use of lug | |||||
plates for the connections. |
|
| |||
The following table shows the connection | |||||
distances and connection cables provided | |||||
that | |||||
vinyl sheath cables) are used. |
|
| |||
Maximum extension | 100 m | 260 m | 410 m | 500 m | |
(reference) | |||||
|
|
|
| ||
Conductor | 1.0∅mm | 1.6∅mm | 2.0∅mm | 2.6∅mm | |
diameter | and more | and more | and more | and more |
Control signal cables
These cables should be connected only when it is required to control the camera using the
tension distance is 1,200 m. | |||
A | TX+ | Connect to the other | |
B | TX- | side in pairs like this. | |
C | RX+ | Connect to the other | |
D | RX- | ||
side in pairs like this. | |||
|
|
Genlock connection
With some systems, when the external sync signal is a composite video or black burst sig- nal genlocking by applying an external sync input requires the horizontal phase (H PHASE) and colour phase (SC COARSE) to be adjusted.
MEMO
•Genlocking is not possible with a signal containing too much jitter, such as a VCR or videodisc playback signal.
•For details, consult a JVC authorized dealer.
MEMO
•If thin cables are used (i.e. with a high resistance), a significant voltage drop will occur when the unit is at its maximum power consumption. Either use a thick cable to restrict the voltage drop at the camera side to below 10%, or place the power supply near to the camera. If voltage drop occurs during operation, the performance will be unstable.
•Attach the cable conductors so that they do not come into contact with the drop prevention wires.
•Do not allow input from both a DC 12 V and AC 24 V power supply at the same time.
•When using a DC 12 V power supply, ensure that the polarities of the cable are correct.
•The AC 24 V power supply should conform to the following:
TK-C1481EG (AC230V)
Y/C OUT
Power cable connect to the commercial AC230V outlet
CAUTION: When you use this camera, the
SYNC IN | VIDEO OUT | as to disconnect easily. |
| ||
|
| SEE INST- |
|
| RUCTION |
POWER |
| MANUAL |