JVC TK-C1480 manual Connection/Installation, RM-P2580 System, TX+ a, Rx+ C, When connecting

Page 7

CONNECTION/INSTALLATION

RM-P2580 System

System with up to 8 cameras

Connecting the control signal cable

(Use a twisted-pair cable for connection.  Page 17.)

Camera 1

MACHINE ID:1 (Menu screen) RX TERM: OFF (switch)

Camera TK-C1480

Camera TK-C1480

Control signal cable

Video signal cable

Power

AC24V

or

cable

DC12V

 

Camera 1

 

control signal

connection terminals

TX+ A

TX

B

RX+ C

RM-P2580

A RX

+

B RX

+

C TX

Connect: Camera TX+ to RM-P2580 RX+ Camera TX– to RM-P2580 RX– Camera RX+ to RM-P2580 TX+

Camera 2

MACHINE ID:2 (Menu screen) RX TERM: OFF (switch)

Camera 8

MACHINE ID:8 (Menu screen) RX TERM: ON (switch)

AC24V or DC12V

Camera

 

 

 

 

 

 

 

TK-C1480

 

 

 

 

 

 

 

AC24V

CAM SW

Time lapse VCR

or

 

 

 

 

 

OUT

SR-L910

DC12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIDEO IN

MONITOR

RX

D

Camera 2

 

control signal

connection terminals

TX+ A

TX

B

RX+ C

RX

D

D TX

Camera RX– to RM-P2580 TX– The A B C D marks indicated on both the camera terminals and the RM-P2580 termi- nals facilitate correct connections. Connect the terminals with identical marks.

 Setting the switches

( Page 10)

TO

CAMERA

TO CAMERA

- -

Remote Control Unit

RM-P2580

ON

 

 

 

CAMERA

COM

 

 

 

 

 

 

SW

 

 

 

 

 

DATA I / O

 

 

 

SERIAL-1

SERIAL-2

 

1

2

3

4

5

6

7

8

 

MONITOR

 

 

 

 

VIDEO INPUT

 

 

 

 

 

 

 

 

 

 

 

 

MONITOR MONITOR

OUTPUT 2

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

OUTPUT OUTPUT

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

VIDEO OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

MONITOR

 

 

 

 

 

 

 

 

OUTPUT 1

MONITOR

SET

 

 

CAMERA

 

 

SETUP

EXT TERM-OFF

ON

MENU

INT/GL

LL

DUPLEXSIMPLEX

RX TERM-OFF

ON

EXT TERM-OFF

INT/GL

DUPLEX

RX TERM-OFF

ON

LL

SIMPLEX

ON

Select the synchronization method of the camera image. Set the switch on all cameras to LL (Line Lock) and match with the V. PHASE. ( Page 26.)

Set this switch to the DUPLEX

* If the setting is changed, be absolutely sure to

switch on the power again.

NOT USED

NOT USED

This is the connected example of the TK-C1480U or TK-C1480E. When controlling with any system except the RM-P2580, execute proper settings using switches and menu screens according to the systems used. ( Page 14) MEMO

VIDEO

DC

IRIS

Set this switch to ON (signal termination ON) only on the camera placed at the end of the control signal cable. Set to OFF on all other cameras.

When operating a system using the RM-P2580, several cameras (up to 8) can be connected and used on one control signal cable. Consequently, an incorrect switch setting on just a single camera will cause the entire system to work incorrectly.

Confirm switch settings on the screen as follows.MONITOR screen

qConfirm that the image from the camera to be checked

(example showing camera ID as “05”)

 

is displayed on the monitor.

 

w Turn OFF and then ON the AC 24 V power to the

 

 

 

 

camera to be checked.

 

 

 

 

e The camera begins the initial operation and charac-

 

 

 

 

ters similar to those shown in the illustration on the

 

 

 

 

right appear on the monitor screen.

 

 

 

 

r Confirm that “DUPLEX” and “ID-□□ are displayed

 

 

 

 

and that the ID number is the correct number (the

P R O T O C O L : D U P L E X

I D - 0 5

 

 

 

 

number should be the same as the number of the

 

 

 

 

VIDEO INPUT terminal to which the camera is con-

 

 

 

 

nected on the rear panel of the RM-P2580).

“DUPLEX”

should

The number shown in the

t If wrong, set the camera ID again.

be displayed.

□□ part of ID-□□

 

should be correct.

E-12

 

 

 

 

 

 

Setting on the MENU screen ( Page 33)

* If the setting is changed, escape from the menu screen once, and definitely switch on the power again.

C OMMUN I C A T I O N

 

Set to M.DROP

 

Set to M.DROP when the RM-P2580 is used

 

 

S T Y L E

M . DROP

as a remote control unit. When controlling

MACH I NE I D

1

from another machine, make sure that it

 

 

 

 

matches the communication system used.

MACHINE ID setting switches

Set this item to match the RM-P2580 VIDEO

INPUT terminal number for each camera.

When connecting

Turn OFF the power supply to all equipment to be used before making connections.

Carefully read the Instructions for each piece of equipment to be used before making connections.

For the appropriate connection cables and the length of these, carefully read “Connections on the back” on page 16.

The control signal cable cannot be used for loop connection.

E-13

Image 7
Contents Colour Video Camera TK-C1480TK-C1481 Serious damage to the appliance Important SafeguardsSafety Precautions Memo FeaturesOperating Precautions IntroductionSET Controls, Connectors and IndicatorsDuplex INT/GLNot Used TX+ a CONNECTION/INSTALLATIONWhen connecting RM-P2580 SystemGND ProceduresDC Iris Video Iris VideoAs to disconnect easily Connections on the backMemo TK-C1481EG AC230VCONNECTION/INSTALLATION Mounting the camera With a fixed-focus lens Lens adjustmentBack focus adjustment Level adjustmentAuto white balance control adjustment Menu SettingSetting the menu Word Colour is displayed as Color on the TK-C1480U Menu Setting The flow of menu screenTK-C1480U does not display these characters Normal Sync Adjust ScreenALC Settings Screen ShutterBLC OFFPriority MotionMotion Detect Screen Video Adjust ScreenMotion Detect Screen Communication Screen BLC Editting Screen Manual Adjustment of White BalanceScreen Camera Title Setting Others Installing the ferrite coreSpecifications Dimensions Unit mm