JVC TK-C1480 manual Sync Adjust Screen, ALC Settings Screen, Shutter, Normal

Page 14

MENU SETTING

 

 

SYNC ADJUST Screen

 

This executes the setting regarding synchronization.

 

Item

Functions and set values

Initial value

Item

Functions and set values

Initial value

SHUTTER

This sets the electronic shutter as well as the ExDR (Extended

NORMAL

(ExDR)

 

 

V PHASE

HPHASE

SC COARSE

SC FINE

This adjusts the vertical synchronization to those of other cameras when a selector switch for the synchronizing system on the side is at LL. (50Hz (60Hz) power region only. ( ): TK-C1480U) When it is not set to LL, “---” will appear, disabling change the set value. TK-C1480U [Set value: –131 to 0 to 131] TK-C1480E and TK-C1481EG [Set value: –156 to 0 to 156]

This adjusts the horizontal synchronization to those of other cameras and systems when a selector switch for the synchronizing system on the side is at INT/GL. When external signals are not input, “---” will appear, disabling change the set value. [Set values: –16 to 0 to 16]

Coarse adjustment of the SC phase in gen-lock operation. The SC phase can be varied by up to 90° in each direction. Adjust with reference to another camera (or system) and together with the SC FINE adjustment. Adjust SC COARSE and SC FINE only after adjusting H PHASE. When it is not set to GL, “---” will appear, disabling change the set value. [Set values: 0°, 90°, 180°, 270°]

Fine adjustment of the SC phase in gen-lock operation. When it is not set to GL, “---” will appear, disabling change the set value. [Set values: 0 to 255]

0

0

0°

128

Dynamic Range).

 

The use of an electronic shutter function enables shooting

with proper brightness, as more brightness results in higher

shutter speed.

 

The ExDR function allows even the shooting of a subject

having different luminous flux density by composing a picture

shot at 1/100 (1/120) sec. shutter speed with a picture shot

by a high-speed shutter. (

): TK-C1480U

NORMAL: This fixes the shutter speed to 1/50 (1/60).

 

The ExDR does not function.

MANUAL: This sets the shutter speed by the item

 

SHUTTER SPEED on the SHUTTER screen.

 

The ExDR does not function.

 

When SENSE UP is functioning, MANUAL

AUTO:

cannot be selected. (Not displayed on MENU)

This automatically switches the shutter speed

 

according to brightness.

 

The ExDR does not function.

 

The item FAST LIMIT on the SHUTTER (ExDR)

M.ExDR:

screen sets a maximum shutter speed value.

This is used when shooting a subject with

 

difference in a luminous flux density in the screen

 

under a fixed illumination condition, and so on.

 

During ExDR mode, the item M.ExDR.SPEED on

 

the SHUTTER (ExDR) screen sets the composing

 

high shutter speed. It is possible to set only when

 

the items BLC and SENSE UP are OFF. What’s

 

more, the ExDR LEVEL sets the signal level of

A.ExDR:

the composing high-speed shutter.

This is used when the subjects having different

 

luminous flux densities are continuously used

 

night and day in the situation where both indoor

 

and outdoor subjects are mixed in existence, and

ALC SETTINGS Screen

 

This makes automatic adjustments according to brightness.

 

Item

Functions and set values

Initial value

IRIS LEVEL

Adjusts the brightness level of the video signal.

NORMAL

To lower the brightness level ... Decrease the value

To raise the brightness level .... Increase the value [Set values: –5 to NORMAL to 5]

AVERAGE:

Sets the exposure detection as a ratio of the average value

8 : 2

PEAK

and the peak value.

 

 

• AVERAGE value large: Increase the AVERAGE value

 

 

when portions other than the highlighted areas of the

 

 

screen are dark and look corrupted. (Ex. 10:0)

 

 

• PEAK value large: Increase the PEAK value when

 

 

halation occurs in the highlighted areas of the screen.

 

 

(Ex. 5:5)

 

 

[Set values: 10:0, 9:1, 8:2, 7:3, 6:4, 5:5]

 

so forth. During ExDR mode, the composing

shutter speed automatically varies according to

the contrast of a subject. This is set when shooting

the subject with changing brightness.

This can be set only when the item BLC is OFF.

What’s more, the ExDR LEVEL sets the signal

level of the composing high-speed shutter.

MEMO

Do not set to A.ExDR when using a manual lens.

When M.ExDR mode or A.ExDr mode is used, the border between a bright part and a dark part can be coloured (cyan, orange, etc.), but this is not a malfunction.

*When the SHUTTER (ExDR) item is set to NORMAL, the following items (SHUTTER SPEED, FAST LIMIT, ExDR LEVEL, and M.ExDR SPEED) cannot be changed.

SHUTTER

This sets a shutter speed when MANUAL is set.

1/120

SPEED

The AUTO, M. ExDR, A. ExDR set value is displayed as

(1/100)

 

“- - -” and cannot be changed

 

 

 

 

[Set values: 1/120 (1/100), 1/250, 1/500, 1/1000, 1/2000,

 

 

1/4000, and 1/10000]

(

):TK-C1480U

 

E-26

E-27

Image 14
Contents Colour Video Camera TK-C1480TK-C1481 Important Safeguards Serious damage to the applianceSafety Precautions Introduction FeaturesOperating Precautions MemoControls, Connectors and Indicators SETNot Used INT/GLDuplex RM-P2580 System CONNECTION/INSTALLATIONWhen connecting TX+ aVideo ProceduresDC Iris Video Iris GNDTK-C1481EG AC230V Connections on the backMemo As to disconnect easilyCONNECTION/INSTALLATION Mounting the camera Level adjustment Lens adjustmentBack focus adjustment With a fixed-focus lensSetting the menu Menu SettingAuto white balance control adjustment TK-C1480U does not display these characters Menu Setting The flow of menu screenWord Colour is displayed as Color on the TK-C1480U Shutter Sync Adjust ScreenALC Settings Screen NormalMotion OFFPriority BLCVideo Adjust Screen Motion Detect ScreenMotion Detect Screen Communication Screen Screen Manual Adjustment of White BalanceBLC Editting Screen Camera Title Setting Dimensions Unit mm Installing the ferrite coreSpecifications Others