Connecting
1.Attach the fall prevention wire to the camera, followed by attaching it to the ceiling slab (Fall prevention wire is not included.)
2.Connect the video signal cable. (A pg. 14)
Lower the cover and connect the connectors. Upon connecting, cover the connectors using the protection cover.
3.Connect the input power supply cable. (A pg. 16)
4.Connect the alarm
5.Wrap insulation tape around cables.
6.Insert the camera unit into the ceiling hole.
Mounting
1.Align j with the shooting direction when mounting the camera.
2.Fasten the camera. (x3 locations)
A Press the screw head of the ceiling mount bracket all the way in using a cross screwdriver.
B With the screw pressed in using the screwdriver, turn about 90 in the clockwise direction, followed by pulling out the screwdriver.
C The ceiling mount bracket is attached to the ceiling and the camera fastened.
NOTE:
Dismantle the camera upon turning the screw heads of the ceiling mount bracket (x3) by 90 in the counterclockwise direction.
6.
Fall prevention | 2. |
wire | |
(not supplied) |
Protection cover
1.
Alarm signal cable
3.4.
Solder or crimp
Insulation tape
Wrap with tape
5.
Input power supply cable
1.
RONTPU |
|
F |
|
Align with shooting direction | 2. |
B
A
Adjusting Images
After mounting is completed, adjust the
images while checking the actual image. (A pg. 23 AAdjusting ImagesB)
19