4.[WHT.BAL.] ATW/MANUAL selection switch.

For selecting whether to adjust the white balance automatically or manually.

When the setting is changed from manual to ATW, the setting values in the manual mode will be reset. The camera switches to the same mode as with pressing the [RESET] button.

(Default setting: ATW)

NOTE:

The white balance of this camera is preset to use under sunlight or halogen lamps, and may not be properly adjusted when used under artificial lights such as fluorescent lights.

5.[BLC] Backlight compensation switch.

When the object is placed against the light, setting this to AONB increases the iris aperture by 1 stop and the object will appear clearer. (Default setting: OFF)

6.[DAY/NIGHT] Easy Day & Night switch.

To capture a subject with continually changing brightness (day/night), set this switch to AONB. The camera automatically captures the image in color when the subject is bright, and in black and white mode when it is dark. (Default setting: OFF)

NOTE:

When this item is set to AONB, the AGC feature will automatically be set to AONB regardless of the [AGC] Switch 1 setting.

The Easy DAY & NIGHT feature on this camera uses a sensitized black and white mode unlike other black and white surveillance cameras that use infra-red lighting.

Sensitivity increases in the case of black- and-white images. The screen may therefore appear rougher and white spots may increase.

7.[RESERVED]

Not used. Ensure to set this to AOFFB before using the camera.

(Default setting: OFF)

8.[RESET/SPOT] RESET/SPOT CORRECTION selection switch.

RESET:

The [RESET/SPOT] button is used as a [RESET] button.

SPOT:

The [RESET/SPOT] button is used as a [SPOT] button. (A pg. 28)

(Default setting: RESET)

D [IRIS LEVEL] Iris level adjustment

For adjusting the level of the automatic aperture control lens. This adjustment only needs to be made when required. Use this to accommodate particular shooting conditions. To darken image: Counterclockwise (L side) To brighten image: Clockwise (H side)

NOTE:

Prior to adjusting the aperture level, ensure to set the [AGC] Switch 1 of the function selection switch C to AOFFB. Otherwise, when the level is turned too far toward L, the AGC function activates increasing sensitivity and the picture may look uneven.

E [FOCUS ADJUST] focus adjustment button

Use this to adjust the lens focus.

Upon pressing, the lens aperture will open up for about 30 seconds such that the depth of field becomes shallower, thus enabling focus to be easily adjusted. (A pg. 24)

NOTE:

The electronic shutter functions automatically upon pressing the focus adjustment button and the screen may flicker. However, this is not a malfunction.

F Focus adjustment ring

Move this to the left/right to adjust the focus.

G Zoom adjustment ring

Move this to the left/right to adjust the field angle.

11

Image 11
Contents For Customer Use TK-C215V4 TK-C215V12Business users Other Countries outside the European Union Safety PrecautionsInformation for USA  Information Important Safeguards Contents Characteristics Note on consumable parts TK-C215V12 only Operating PrecautionsCamera Name of PartsCamera Interior Sync Synchronization system selection switch Setting the Lens Switches TK-C215V4RESET/SPOT RESET/SPOT button B, +/- R/B, +/- adjustment buttonRESET/SPOT RESET/SPOT Correction selection switch WHT.BAL. ATW/MANUAL selection switchBLC Backlight compensation switch DAY/NIGHT Easy Day & Night switchPosition Select Position Select button Setting the Lens and Switches TK-C215V12Alarm Position status indication lamp Trigger Alarm alarm input mode selection switchAbout Connection Cables Video signal cablesDC 12 V or AC 24 V power supply cable ‹ Polarity of alarm signals Electrical Specifications of Alarm Input TerminalsVideo Monitor System diagramSelecting a mounting method Mounting the CameraGetting Started Embedding the camera to the ceiling  Setup Mounting  Connecting Adjusting Images Open a hole in the ceiling. R 30 mm, 1 1/8 inches Fasten the camera by tightening the camera fastening screw Turn the camera unit in the clockwise directionMount by allowing the cable to exit from the side When mounting the camera to the electrical boxAdjusting Images Mounting the test monitor Adjusting ImagesAdjusting the camera direction Adjusting brightness Adjusting the field angle/focus/ brightness  TK-C215V4Adjusting field angle Adjusting focus‹ Registering home position BAdjust the focusAdjust the brightness  TK-C215V12 TK-C215V12 ‹ Registering alarm position Mount the dome cover Mounting the Inner DomeMounting the Dome Cover Mount the inner dome‹ TK-C215V12 White-spot correction‹ TK-C215V4  General Specifications Camera  Lens‹ When embedded  External Dimensions Unit mm inches‹ When cover is attached Focus chart TK-C215V4/TK-C215V12 Dome Camera