Panasonic AK-HCU200ES, AK-HCU200PS operating instructions Specifications

Page 19

Specifications

Power supply:

100 V to 240 V AC, 50/60 Hz

Power consumption: 170 W

(Without CAMERA connected: 32 W)

Capacity for supplying power to a camera: 190 V DC, 0.6 A

indicates safety information.

Operating temperature:

0 °C to 40 °C (32 °F to 104 °F)

Humidity:

10 % to 90 % (no condensation)

Dimensions (Width × Height × Depth): 424 mm × 88 mm × 400 mm

(16-11/16 inches × 3-7/16 inches × 15-3/4 inches) [Excluding protrusions]

Weight:

Approx. 6.6 kg (14.6 lb)

Video output:

HD-SDI/SD-SDI

4lines (2 lines shared with picture monitor output *2) Analog composite

1 line (1 line shared with picture monitor output *2)

Return input:

HD-SDI/SD-SDI (switched depending on the setting) 2 lines

VBS 1 line

Prompter input: Analog composite

1 line

Reference input:

Black burst/tri-level *1

1 line (1 loop-through line)

Microphone output: 0 dBm/600 Ω

2 lines (XLR, 3-pin, male)

Intercom:

Input: –55 dBu to –10 dBu

Output: 100 mW (max.) (XLR, 5-pin, female)

COMMUNICATION: Intercom input/output:

(0 dBm, 600 Ω, RTS/4W *2)

2 lines (1/2 *2)

PGM input (0 dBm/600 Ω) 1 line

Tally input (red, green) 1 input each

ROP interface: RS-422

1 line, 12 V output

MSU interface: RS-422

1 line, GPI for control

LAN port:

For computer connection

1 line (10Base-T/100Base-TX, RJ45, crossover cable, category 5 or above)

*1: The black burst signal and tri-level sync signal of the reference input are recognized automatically.

*2: Depending on the setting, only one of them can be selected at one time.

Note

For details on the maximum lengths of connection cables, consult your dealer.

Inrush current, measured according to European standard EN55103-1, on initial switch-on: 7 A, after a supply interruption of 5 s: 11 A

19

Image 19
Contents AK-HCU200P AK-HCU200PS AK-HCU200E AK-HCU200ES Pp Come aprire i file dei manuali di istruzioni per l’uso It can be downloaded from the home page of Adobe SystemsRead this first! For AK-HCU200P, AK-HCU200PS FCC Note Read this first! For AK-HCU200P, AK-HCU200PSRead this first! For AK-HCU200E, AK-HCU200ES Performance level Read this first! For AK-HCU200E, AK-HCU200ESFor Continental EUROPE, ETC. Not to be used in the U.K How to replace the fuseContents Http//pro-av.panasonic.net IntroductionAccessories FeaturesPrecautions for use Precautions for Installation Connections System configurationParts and their functions Avbs connector OUT/PM HD/SD SDI OUT connectors 1, 2, 3/PM, and 4/PM? Return in connectors HD/SD SDI 1 and HD/SD SDI  Prompt connector Grounding terminal Signal GND Iincom switches 1 Tally switch MAKE/V KAC power socket ACTroubleshooting ZzWeb settings Unit mm inch AppearanceSpecifications For business users in the European Union