Chapter
Figure 3-15 Removing and Replacing a Motherboard CMOS Battery
2
+
1
1
Motherboard CMOS battery socket (positive side toward chassis wall)
2
Battery retaining clip
Installing a Trusted Platform Module (TPM)
The qualified and supported part numbers for this component are subject to change over time. For the most
http://www.cisco.com/en/US/products/ps10493/products_data_sheets_list.html
To install or replace a trusted platform module (TPM), follow these steps:
Step 1 Remove a TPM:
a.Power off the server as described in the “Shutting Down and Powering Off the Server” section on page
b.Disconnect all power cords from the power supplies.
c.Slide the server out the front of the rack far enough so that you can remove the top cover. You might have to detach cables from the rear panel to provide clearance.
Caution If you cannot safely view and access the component, remove the server from the rack.
d.Remove the top cover as described in the “Removing and Replacing the Server Top Cover” section on page
e.Remove the PCIe riser card assembly to provide clearance to the TPM.
See the “Replacing a PCIe Riser Card Assembly” section on page
f.Remove the securing screw that holds the TPM to the motherboard standoff (see Figure
g.Lift up on both ends of the TPM to free it from the socket on the motherboard.
| Cisco UCS C210 Server Installation and Service Guide |
|