Table B-1

Supported Power Cords for the Server (Continued)

 

 

 

 

 

 

 

 

 

 

Length

Power Cord Reference

 

 

 

 

 

Description

 

Feet

 

Meters

Illustration

 

 

 

 

 

CAB-N5K6A-NA

8.2

 

2.5

Figure B-12

Power Cord, 250 VAC 13 A NEMA 6-15 Plug,

 

 

 

 

North America

 

 

 

 

 

 

 

 

 

 

CAB-9K12A-NA

8.2

 

2.5

Figure B-13

Power cord, 125 VAC, 13 A, NEMA 5-15 Plug

 

 

 

 

North America

 

 

 

 

 

 

 

 

 

 

CAB-C13-C14-JMPR

2.2

 

0.7

Figure B-14

Cabinet Jumper Power Cord, 250 VAC 13 A,

 

 

 

 

C13-C14 Connectors

 

 

 

 

 

 

 

 

 

 

AC Power Cord Illustrations

This section contains the AC power cord illustrations.

Figure B-2

SFS-250V-10A-AR

 

 

2500 mm

 

 

Cordset rating: 10 A, 250/500 V MAX

 

 

Length: 8.2 ft

 

Plug:

 

 

EL 219

 

 

(IRAM 2073)

Connector:

 

 

EL 701

 

 

(IEC60320/C13)

186571

 

 

Figure B-3

CAB-9K10A-AU

 

 

Cordset rating: 10 A, 250 V/500V

 

 

Length: 2500mm

 

Plug:

Connector:

 

EL 701C

 

EL 206

 

(IEC 60320/C15)

186581

A.S. 3112-2000)

 

 

 

Cisco UCS C210 Server Installation and Service Guide

 

OL-20887-02

B-3

 

Image 89
Contents Americas Headquarters Covers UCS C210 Server Generations M1 and M2Page N T E N T S Replacing a SAS Extender or SAS Expander Card KVM Cable B-1 OL-20887-02 Audience Related DocumentationOrganization Chapter Title DescriptionBewaar Deze Instructies ConventionsAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseGuarde Estas Instruções Aviso Instruções Importantes DE SegurançaGEM Disse Anvisninger Xii Obtaining Documentation and Submitting a Service Request Xiv Overview Feature or Component Cisco UCS C210 Server DVD+RW, DVD-R, DVD-ROM, DVD-RW, +R DL Chapter Installing the Server Unpacking and Inspecting the Server Shipping Box ContentsInstallation Guidelines Preparing for InstallationRequired Equipment Slide Rail Adjustment RangeRack Requirements Installing the Server Into a Rack Attaching a Slide-Rail Assembly Attaching Mounting Brackets to the Server Attaching the Cable Management Arm Connecting and Powering On the Server Standalone Mode Initial Server SetupOL-20887-02 Cisco UCS C210 Server Installation and Service Guide NIC Modes and NIC Redundancy Settings Updating the Bios and Cimc Firmware System Bios and Cimc FirmwareAccessing the System Bios Motherboard Jumpers Service Jumper LocationsUsing the Bios Recovery Jumper J1E5 to Recover Corrupt Bios Clearing the Cimc Admin Password Using Jumper J45 Using the Clear Cmos Jumper J1E6 Clearing the Bios Admin Password Using Jumper J1E4 Chapter Cisco UCS C210 Server Installation and Service Guide Cisco Integrated Management Interface Cimc Server Configuration UtilityServer Monitoring and Management Tools Front Panel LEDs Status LEDsLED Name State 2shows the names and locations of the rear panel LEDs Rear Panel LEDsRear Panel LEDs LED Name State Preparing for Component Installation Shutting Down and Powering Off the Server Removing and Replacing the Server in a Rack Removing the Top Cover of the Server Removing and Replacing the Server Top CoverRemoving the Front Cover of the Server Removing and Replacing the Server Front CoverReplaceable Component Locations top view Replaceable Component LocationsInstalling or Replacing Components Installing Hard Drives and Solid State Drives Removing and Replacing Hard Drives and SSDs PSU1 Installing Power SuppliesInstalling a DVD Drive Removing and Replacing a DVD drive Installing a Fan Tray Fan tray Fan tray securing screws two on each side Memory Performance Guidelines and Population Rules Installing DIMMsFront of Server Rear of ServerMemory Population Rules Memory Mirroring and RAS Dimm Installation Procedure13 Removing and Replacing Memory Modules CPU Replacement Procedure Installing CPUs and HeatsinksChapter 14 Removing and Replacing CPUs and Heatsinks Installing a Motherboard Cmos Battery 15 Removing and Replacing a Motherboard Cmos Battery Installing a Trusted Platform Module TPMTPM Replacing a PCIe Riser Card Assembly Riser card assembly top view Replacing a PCIe Card Replacing a PCIe CardChapter 19 Removing and Replacing a PCIe Card How to Identify Which Power Supply Model is in Your Server Resolving Insufficient Memory Space to Execute Option ROMs Resolving Insufficient 16-Bit I/O Space SAS Expander Replacing a SAS Extender or SAS ExpanderSAS Extender Replacing a SAS Extender or SAS Expander Card 22 and then connect the cable to the socket on the adapter Replacing an LSI MegaRAID Battery Backup Unit22 Removing and Replacing an LSI BBU Installing a Mezzanine Card Mezzanine card retaining posts three Chapter Cisco UCS C210 Server Installation and Service Guide Description Specification Physical SpecificationsPower Specifications Environmental SpecificationsSupported Components Part Number KVM CableDescription Feet Meters Illustration Supported Power Cords and PlugsLength This section contains the AC power cord illustrations AC Power Cord IllustrationsCAB-9K10A-EU CAB-9K10A-SW CAB-N5K6A-NA CAB-9K12A-NA OL-20887-02 Supported RAID Controllers and Required Cables RAID Controller ConsiderationsRAID Levels Required Cables Max Internal Opt Controller Style DrivesRAID Controller Cabling Enabling the Mezzanine Card RAID Controller in the BiosIntegrated ICH10R How to Determine Which Controller Is in Your ServerHow To Launch Option ROM-Based Controller Utilities From your For More Information OL-20887-02 Installation for Cisco UCS Integration OL-20887-02