Axis Communications ptz dome network camera user manual Multi-Connector Cable sold separately

Page 47

AXIS P5532 PTZ Dome Network Camera

Multi-Connector Cable (sold separately)

Multi-Connector Cable (sold separately)

When connecting external equipment to the Axis product, a multi-connector cable (available from Axis) is required in order to maintain the product’s IP rating. The multi-connector cable can be purchased from your Axis reseller.

Connect the multi-connector cable to the product’s multi-connector (see page 5 ). The cable provides the following connectors:

Note

See page 54 for technical specifications.

Power connector - 3-pin terminal block used for power input. See image below.

Audio in (pink) - 3.5 mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).

Audio out (green) - 3.5 mm output for audio (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio out.

I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:

Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The output will show as active (shown under System Options > Port & Devices > Port Status) if the alarm device is activated.

Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input becomes active (shown under System Options > Port & Devices > Port Status).

Function

Pin

Notes

Specifications

 

 

 

 

GND

1

Ground

 

 

 

 

 

3.3 V DC Power

2

Can be used to power auxiliary equipment.

Max load = 250 mA

 

 

Note: This pin can only be used as power out.

 

 

 

 

 

Configurable

3–6

Digital input — Connect to GND to activate, or leave floating

0 to +40 V DC

(Input or Output)

 

(unconnected) to deactivate.

 

 

 

Digital output — Internal connection to ground when

Max load =100 mA

 

 

activated, floating (unconnected) when deactivated. If used

Max voltage = +40 V DC

 

 

with an external relay, a diode must be connected in parallel

 

 

 

with the load, for protection against voltage transients.

 

 

 

 

 

47

Image 47
Contents Axis P5532 PTZ Dome Network Camera Equipment Modifications About this documentLiability Intellectual Property RightsAxis P5532 PTZ Dome Network Camera Table of ContentsPerformance considerations Symptoms, possible causes and remedial actionsHardware overview ConnectorsHardware overview Color Indication LED indicatorsMidspan LED indicators Start a browser Internet Explorer, Firefox, Safari Accessing the productAccessing the product Access from a browserClick Create self-signed certificate Access from the InternetSet the root password Network TCP/IP AdvancedControls on the Live View Live ViewAMC Audio controls Axis Media Control viewer toolbarPTZ Controls Axis P5532 PTZ Dome Network Camera Axis Media Control AMC How to stream H.264Media streams Media streamsQuickTimeTM. The following paths can be used Alternative methods of accessing the video streamJava applet supports simplex audio with G.711 encoding Accessing audio streamsBasic Setup Setting up the productSetting up the product Pixel Counter Video and AudioVideo and Audio Video Stream264 Camera SettingsStream Profiles ImageWhite balance Exposure SettingsImage settings Image AppearanceOverlay image Audio SettingsOverlay Privacy MaskG711 G726 Audio InputAudio Output Audio ClipsLive View Config Default viewer for browsersLive View Config Browser Viewer Description Viewer SettingsUser Defined Links Output ButtonsAxis P5532 PTZ Dome Network Camera Gatekeeper Preset PositionsPTZ Pan Tilt Zoom PTZ Pan Tilt ZoomLimits Guard TourOsdi Zones AdvancedControls Operator Same as administrator but with lower priorityControl Queue Motion Detection Set up motion detectionDetectors DetectorsAudio detection Applications ApplicationsEvents EventsGo to Events Action Rules and click Add Setting Up an Action RuleConvert Event Types to Action Rules PTZ ControlGo to Events Recipients and click Add RecipientsSchedules Recipient Use with actionGo to Events Recurrences and click Add RecurrencesContinuous recording RecordingsRecordings Recording ListAxis P5532 PTZ Dome Network Camera Users System OptionsSystem Options SecurityAudio Support Date & TimeIeee IPv6 Address Configuration Basic TCP/IP SettingsNetwork IPv4 Address ConfigurationAdvanced TCP/IP Settings NAT traversal port mapping for IPv4 Link-Local IPv4 AddressSmtp email QoS Quality of ServiceBonjour StorageUPnPTM RTP/H.264Ports MaintenancePorts & Devices Network ShareLogs & Reports SupportSupport Overview System OverviewPlain Config Reset to factory default settingsScripting File UploadFunction Pin Specifications Multi-Connector Cable sold separatelyMulti-Connector Cable sold separately Connector DC power input Connection diagramChecking the firmware TroubleshootingTroubleshooting Emergency recovery procedureProduct cannot be accessed from a browser Symptoms, possible causes and remedial actionsProblems setting the IP address Problems with the H.264 format Product is accessible locally but not externallyNo images displayed on web Video and image problems, generalSetup Video & Audio Camera Settings Problems uploading filesPoor audio quality SettingsStorage and disk management problems No audioTechnical Specifications Technical SpecificationsFunction/group Specifications Network Security Maintenance Installation aidsMemory Power ConnectorsPerformance considerations Ver M1.10 Axis P5532 PTZ Dome Network Camera