Bosch Appliances VG4-300, VG4-200, VG4-500I Advanced Mode VCA Profiles, VCA configuration

Page 103

102 en Configuring the IP AutoDome

VG4 Modular Camera System

 

 

 

NOTICE!

 

In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in

 

mind when assigning the profile (see Section 10.16 Advanced Mode: Encoder Profile, page 78).

 

 

 

Audio

 

Select the On option if you wish to additionally transmit a standalone G.711 encoded audio

 

stream with alarm connections.

10.45

Advanced Mode: VCA

 

The IP AutoDome contains an integrated video content analysis (VCA), which can detect and

 

analyze changes in the signal using image processing algorithms. Such changes can be due to

 

movements in the camera's field of view.

 

You can select various VCA configurations and adapt these to your application as required.

 

The Silent MOTION+ configuration is active by default. In this configuration, metadata is

 

created to facilitate searches of recordings; however, no alarm is triggered.

 

You can switch off the video content analysis completely if the device's full power is to be

 

made available for the encoder.

 

1.

Select a VCA configuration and make the required settings.

 

2.

If necessary, click the Default button to return all settings to their default values.

10.46

Advanced Mode: VCA Profiles

 

You can configure two profiles with different VCA configurations. You can save profiles on

 

your computer's hard drive and load saved profiles from there. This can be useful if you want

to test a number of different configurations. Save a functioning configuration and test new settings. You can use the saved configuration to restore the original settings at any time.

NOTICE!

If computing power becomes short, the highest priority is always the live images and recordings. This can lead to impairment of the video content analysis. You should therefore observe the processor load and optimize the encoder settings or the video content analysis settings as necessary.

1.Select a VCA profile and enter the required settings.

2.If necessary, click the Default button to return all settings to their default values.

3.Click the Save... button to save the profile settings to another file. A new window is opened, in which you can specify where you want to save the file and what name you want to save it under.

4.Click the Load... button to load a saved profile. A new window opens in which you can select the profile file and specify where to save the file.

VCA configuration

Select one of the profiles here to activate it or edit it.

You can rename the profile.

1.To rename the file, click the icon to the right of the list field and enter the new profile name in the field.

2.Click the icon again. The new profile name is saved.

F.01U.133.268 6.0 2010.03

User’s Manual

Bosch Security Systems, Inc.

Image 103
Contents VG4 Modular Camera System Page Table of Contents VG4 Audio Connections Keyboard Commands by Number Advanced FeaturesUsing the IP AutoDome Pelco On-Screen MenusConfiguring the IP AutoDome Troubleshooting Guide 117 Seconds and ends with a splash screen Powering OnGetting Started Establishing AutoDome ControlBasic Keyboard Operation 2Keyboard CommandsLCD To change or clear an address for a camera with an address Setting the Camera AddressFastAddress To set an address for a camera without an addressTo set or change a password locked command Setting PasswordsSpecial Passwords Password Security LevelOn-Screen Display Menu Navigation Setup MenuCamera Setup Menu OFF ATWAuto Internal60 sec Night ModeRestore DefaultsFast Lens SetupSpot ConstantPTZ Setup Menu Normal OSD Display Setup MenuMoment ARYCommunication Setup Menu Alarm I/O Setup Pressure SetupInputs LowOutputs Outputs Setup MenuOutputs Setup Alarm RelayRule Setup Rule Setup MenuRule None Advanced Feature Setup Advanced Feature Setup Menu available with Series 500i onlyLanguage Menu AutoTrack TimeoutTimeout Period StabilizationInternal Temp Diagnostics MenuAlarm Status BistExtComm Error Security AccessCtfid Access Power Up Events11.1 Alarm Status Submenu Setting AutoPan Mode Common AutoDome User Commands unlocked2Setting Preset Shots To stop a Preposition Tour 4Configuring Preposition ToursSpecifying a Shot or a Sector Title To start Preposition Tour 1 200, 300, and 500i Series6Recording Tours 300 and 500i Series only 5Programming the Inactivity OperationUsing an American Dynamics Controller Setting FastAddress with Alternative ProtocolsAlternative Control Protocols Enter FastAddress Exit Command LockFastAddress New Fast Address Saved Setup Menu 2Using a Pelco ControllerSetting FastAddress with a Pelco Keyboard Hardware Configuration Pelco Protocol Mode2Pelco Keyboard Commands Special Preset Commands Pelco Keyboard CommandsPreset Pelco On-Screen Menus Pelco menu Bosch menu Setup Menu Command Lock lockedBosch Menu locked Outdoor PTZ Setup unlockedCamera Setup unlocked Pelco Camera Setup Menu provides access to camera settingsOther Menus Keyboard Commands by Number Specifying a Shot or a Sector Title, Zone Title menu Enters Zone Title menu. Refer toVG4 Modular Camera System Keyboard Commands by Number en Alarm Rule Examples Advanced FeaturesAlarm Rules 300 and 500i Series Only Controlling Alarm RulesExample 2 Advanced Alarm Rule Example 3 Advanced Alarm Rule using AutoTrack Click Output Option Click the Online Config button and then expand AlarmManual AutoTrack Operation 500i Series OnlyAutomatic AutoTrack Settings and Recommendations Consistent Light Conditions Setting AutoTrack Optimization Parameters2AutoTrack Optimization Dynamic Light ConditionsMotion Detection with Region of Interest 500i Series Only Preset positions 90 throughVirtual Masking 500i Series Only 4Privacy Masking 300 and 500i Series Only7Pre-position Tour Image Stabilization 500i Series OnlyOverview of Features Using the IP AutoDomeBelow Connecting the IP AutoDome to the PCNetwork switch to bypass the Local Area Network LAN System RequirementsAutoDome IP Connection Network Switch Computer Configuring the IP AutoDome CameraInstalling the Required Software Install the software packages using the procedure below 1Changing the Network SettingsUsing the Configuration Manager Network Settings Using the IP AutoDome Web ServerProtected Network 6The LivepageMaximum Number of Connections Protected IP AutoDomeIris open View ControlDigital I/O Audio Function Entering a Keyboard Control CommandTriggering Relay System Log / Event LogNumber Description To Enter a Keyboard Control CommandTo Set a Preset Shot Aux Control TabRecording Video Sequences To View a Preset ShotImage Resolution Saving SnapshotsConnections Audio Line Input SpecificationsWire Specifications 9VG4 Audio ConnectionsEnabling Audio Transmission Click the Transmit Audio radio button to enable for audioTo transmit audio via the IP connection, do the following 5Configuring Gain optional 10.1 Basic Mode Device Access Configuring the IP AutoDomeConfirm password Password10.3 Basic Mode Network 10.2 Basic Mode Date/TimeDhcp Modem 10.4 Basic Mode Encoder Profile10.5Basic Mode Audio DSLStorage medium 10.6 Basic Mode Recording10.7 Basic Mode System Overview 10.8Advanced Mode IdentificationInitiator extension 10.9Advanced Mode PasswordDevice time zone 10.10 Advanced Mode Date/TimeDate format Device date/Device time10.11 Advanced Mode Display Stamping 10.13 Advanced Mode Livepage Functions 10.12 Advanced Mode Appearance10.14 Advanced Mode Logging Isdn 1B 10.15 Advanced Mode Picture Settings10.16 Advanced Mode Encoder Profile Isdn 2BCIF 10.17 Advanced Mode Encoder Streams Transmitted, select Off 10.18 Advanced Mode AudioPicture quality Network10.21 Camera Settings Group 10.23 Advanced Mode Lens 10.24 Lens Settings Group 10.22 Camera Settings Group10.26 Advanced Mode PTZ 10.27 PTZ Settings Group 10.25 Lens Settings Group10.29 Advanced Mode Display 10.30 Display Settings Group 10.28 PTZ Settings GroupScene # 10.31 Display Settings GroupTour Custom Tour 10.32 Display Settings Group10.33 Advanced Mode Alarm 10.34 Input Options Custom Tour PeriodRule Definition 10.35 Output OptionsPhysical Output Creating Alarm Rules 10.36Alarm RulesBasic Alarm Rule Example Output Option 5 Example Click the Type drop-down list and select Transmit Select Output OptionAlarm Rule 1 Example Address Advanced Alarm Rule Example using AutoTrackAudio/BiPhase 10.37Miscellaneous10.38 Logs 10.39 Advanced Mode Storage ManagementLocal Media Activating and Configuring Storage MediaFormatting Storage Media Recording includes 10.40Advanced Mode Recording ProfilesStream profile settings Deactivating Storage Media10.41 Advanced Mode Retention Time Time periods 10.42 Advanced Mode Recording SchedulerHolidays Deleting Holidays10.44 Advanced Mode Alarm Connections 10.43 Advanced Mode Recording StatusDecoder Video transmissionRemote port Video output10.46 Advanced Mode VCA Profiles 10.45 Advanced Mode VCAVCA configuration Sensitivity MOTION+ only Aggregation time sAnalysis type Motion detector MOTION+ onlySelect Area MOTION+ only Trigger delay sMinimum object size MOTION+ only Debounce time 1 s MOTION+ onlyScene too noisy Global changeScene too bright Scene too darkSelect Area 10.47 Advanced Mode VCA Scheduled10.49 Advanced Mode Audio Alarm 10.48 Advanced Mode VCA Event triggeredSMS 10.50 Advanced Mode Alarm E-MailSender name 10.51 Advanced Mode Alarm Task EditorTest e-mail Http browser port 10.52 Advanced Mode NetworkAutomatic IP assignment DNS server addressRCP+ port Interface mode ETHEnable DynDNS Https browser portSnmp 10.53 Advanced Mode AdvancedNtcip 10.54 Advanced Mode Multicasting10.55 Advanced Mode Jpeg Posting 10.57 Advanced Mode Maintenance 10.56 Advanced Mode EncryptionDownload 10.58 Advanced Mode Licenses10.59 Advanced Mode System Overview Maintenance log11.1 VG4 AutoDome Operation and Control Troubleshooting GuideIf O.K., then If using a non-Bosch power supply If O.K., then If there is power to the AutoDome, thenNo camera control If amber LED does not light when given PTZ commands, thenCannot access user SettingsDynamics Keyboard Setting FastAddressDoes not switch If O.K., then Automatically when With an American11.2 VG4 IP AutoDome Video and Control 11.3VG4 IP AutoDome Audio Audio Connections with an IP-enabled VG4 AutoDomeAudio Connections with an Analog standard VG4 AutoDome Typical Audio Connections for an Analog AutoDome Problem Solution No Audio Poor Audio Problem Solution If O.K., thenProbably not the source of audio problems 328 ftUser Command Table En User Command Table VG4 Modular Camera System Block Appendix FastAddress ConversionsGroup Numerics IndexVG4 Modular Camera System Index en En Index VG4 Modular Camera System Jpeg En Index VG4 Modular Camera System PTZ En Index VG4 Modular Camera System VIP XD Page Page Bosch Security Systems, Inc
Related manuals
Manual 76 pages 38.12 Kb

VG4-500I, VG4-200, VG4-300 specifications

Bosch Appliances is renowned for its commitment to quality and innovation, and their VG4 series of ventilation hoods is no exception. The VG4-300, VG4-200, and VG4-500I models are designed to cater to various kitchen needs, providing effective air filtration while maintaining aesthetic appeal.

The VG4-300 model is characterized by its sleek design and robust performance. It features a powerful motor that delivers efficient ventilation, removing smoke, odors, and grease from your kitchen swiftly. One of the standout features is its three-speed fan system, which allows users to select the appropriate level of airflow based on cooking intensity. Additionally, the grease filter is dishwasher-safe, ensuring easy maintenance and longevity.

In contrast, the VG4-200 model is perfect for those seeking a compact yet powerful solution. Designed for smaller kitchens, it doesn’t compromise on performance. This model also offers a three-speed fan, providing sufficient airflow for everyday cooking activities. The LED lighting integrated into the design enhances visibility on your cooktop while adding a modern touch to your kitchen. With a focus on energy efficiency, the VG4-200 operates quietly, allowing for a pleasant cooking experience without distraction.

The VG4-500I model is a standout in the series, designed for larger, more demanding kitchens. With increased airflow capacity, it can handle vigorous cooking styles with ease. It also boasts an advanced filtration system that captures more airborne particles, enhancing indoor air quality. The model features a touch control panel for ease of use, giving users the ability to adjust settings seamlessly. Like its counterparts, the VG4-500I includes LED lighting and dishwasher-safe filters, making maintenance straightforward.

All three models in the VG4 series exemplify Bosch's dedication to advanced technologies. Noise reduction features ensure that the ventilation system operates quietly, allowing conversations in the kitchen without disturbance. Furthermore, the stylish and modern finishes of each model enhance kitchen aesthetics, making them suitable for any decor.

In summary, Bosch Appliances’ VG4-300, VG4-200, and VG4-500I ventilation hoods offer a range of features tailored to meet different culinary needs. From effective air filtration and energy-efficient operation to user-friendly controls and elegant designs, these models are crafted to elevate the cooking experience while ensuring a fresh and clean kitchen environment.