Bosch Appliances VIP X1600 XF manual Installation, Preparations, Installing Modules

Page 13

VIP X1600 XF

Installation en 13

 

 

4 Installation

4.1 Preparations

The VIP X1600 XF base is designed for installation in a switch cabinet. Mounting the unit in a 19-inch rack using the installation material supplied is a quick and easy operation.

It is also possible to operate this as a desktop unit. The four elastic bumpers included in the scope of delivery ensure a non-slip support.

CAUTION!

The unit is designed for indoor operation.

Select a suitable location for installation that guarantees to meet the environmental

!conditions. The ambient temperature must be between 0 and +50 °C (+32 and +122 °F). The relative humidity must not exceed 95% (non-condensing).

The VIP X1600 XF generates heat during operation. During installation, please note the maximum heat value of 170 BTU/h. Ensure that there is adequate ventilation and enough clearance between the unit and heat-sensitive objects or equipment.

Please ensure the following installation conditions:

Do not install the unit close to heaters or other heat sources. Avoid locations exposed to direct sunlight.

Allow sufficient space for running cables.

Ensure that the unit has adequate ventilation. Bear the total heat output in mind, particularly when installing multiple units in a switch cabinet.

When making connections, use only the cables supplied or use appropriate cables immune to electromagnetic interference.

Position and run all cables so that they are protected from damage, and provide adequate cable strain relief where needed.

Avoid impacts, blows and severe vibrations, as these can irreparably damage the unit.

4.2 Installing Modules

Installation of the different modules in the VIP X1600 XF base is described in the relevant Quick Installation Guides and the Installation and Operating Manuals. It is also possible to install, remove and exchange modules during operation.

CAUTION!

!Ensure that Slot 1 is always populated by a module, even when modifying the installation. Malfunctions may occur when the VIP X1600 XF is switched on without a functional module in Slot 1.

Bosch Security Systems

Installation and Operating Manual

F.01U.082.088 V3.5 2008.05

Image 13
Contents VIP X1600 XF Page Table of Contents En Table of Contents About this Manual PrefaceConventions in this Manual Intended UseRating Plate EU DirectivesInstallation and Operation Safety InformationMaintenance and Repair Electric Shock HazardEn Safety Information Configuration and Operation System Requirements for SetupProduct Description Scope of DeliveryRedundant Power Supply Network Video Server HousingOverview of Functions Network InterfacesSFP LED Connections and DisplaysEn Product Description Installing Modules InstallationPreparations Installing and Connecting the VIP X1600 XF Installing in a Switch CabinetPreparations Page Connections En InstallationNetwork Direct iSCSI ConnectionPower Supply Power On/Power OffEn Installation Testing the Network Connection Maintenance and UpgradesUnit Reset RepairsEn Maintenance and Upgrades Appendix TroubleshootingLEDs En Appendix VIP X1600 XF Base SpecificationsEn Specifications Page Bosch Security Systems