Axis Communications M3025-VE user manual Set Power Line Frequency, Controls on the Live View

Page 9

AXIS M3025–VE Network Camera

Access the Product

The default administrator user name root is permanent and cannot be deleted. If the password for root is lost, the product must be reset to the factory default settings. See Reset to Factory Default Settings on page 49.

To set the password via a standard HTTP connection, enter it directly in the dialog.

To set the password via an encrypted HTTPS connection, follow these steps:

1.Click Use HTTPS.

A temporary certificate (valid for one year) is created, enabling encryption of all traffic to and from the product, and the password can now be set securely.

2.Enter a password and then re-enter it to confirm the spelling.

3.Click OK. The password has now been configured.

Set Power Line Frequency

Power line frequency is set the first time the Axis product is accessed and can only be changed from Plain Config (see page 49) or by resetting the product to factory default.

Select the power line frequency (50 Hz or 60 Hz) used at the location of the Axis product. Selecting the wrong frequency may cause image flicker if the product is used in fluorescent light environments.

When using 50 Hz, the maximum frame rate is limited to 25 fps.

Note

Power line frequency varies depending on geographic region. The Americas usually use 60 Hz, whereas most other parts of the world use 50 Hz. Local variations could apply. Always check with the local authorities.

The Live View Page

The controls and layout of the Live View page may have been customized to meet specific installation requirements and user preferences. Consequently, some of the examples and functions featured here may differ from those displayed in your own Live View page. The following provides an overview of each available control.

Controls on the Live View Page

Click View size to scale the image down to 800 pixels wide or to full scale. Only available in MJPEG.

Select a stream profile for the Live View page from the Stream Profile drop-down list. For information about how to configure stream profiles, see page 17.

Click Pulse to activate the product’s output port for a defined period of time. For information about how to enable and configure output buttons, see page 23.

Click the Active/Inactive buttons to manually activate and inactive the product’s output port. For information about how to enable and configure output buttons, see page 23.

9

Image 9
Contents Axis M3025-VE Network Camera Legal Considerations About this DocumentLiability Intellectual Property RightsLearn More SupportAxis M3025-VE Network Camera Table of ContentsPerformance Considerations Network Connector Connectors and ButtonsFor technical specifications, see RJ45 Ethernet connector with Power over Ethernet PoEConnector LED IndicatorsSD Card Slot Control ButtonAccess from a Browser Access the ProductAccess from the Internet Set the Root PasswordLive View Set Power Line FrequencyControls on the Live View Click Use HttpsAxis Media Control viewer toolbar Go to Setup EventsPTZ Controls Manual TriggerAxis M3025-VE Network Camera How to Stream H.264 Media StreamsAxis Media Control AMC QuickTimeTM. The following paths can be used Alternative Methods of Accessing the Video StreamAxis M3025-VE Network Camera Basic Setup Set Up the ProductVideo Click Save to apply the new settingsVideo Stream Pixel Counter264 Stream ProfilesExposure Settings Camera SettingsImage Appearance White BalanceOverlay View AreaOverlay Image Go to Video Video Stream and select the Image tabGo to Video Overlay Image Use Overlay Text in an Action RuleGo to Events Action Rules Click Add to create a new rulePrivacy Mask Default Viewer for Browsers Configure the Live ViewViewer Settings Browser Viewer DescriptionUser Defined Links Go to Setup Live View ConfigOutput Buttons For more information about I/O ports, see I/O Ports onPreset Positions PTZ Pan Tilt ZoomAdvanced Axis M3025-VE Network Camera Camera Tampering DetectorsMotion Detection Go to Detectors Camera TamperingMotion Detection Parameters Set Up Motion Detection WindowsAxis M3025-VE Network Camera Go to Setup Applications Install ApplicationApplications Application LicensesAxis M3025-VE Network Camera Events Set Up Action RulesConvert Event Types to Action Rules Go to Events Action Rules and click AddTriggers Input SignalDetectors HardwareAdd Recipients ActionsRecipient Types Recipient Use with action Set Up Email RecipientsCreate Schedules Set Up RecurrencesTo create a new schedule Go to Events Schedules and click AddRecording List RecordingsContinuous Recording Go to Recordings ListLanguages Security System OptionsUsers IP Address FilterIeee CertificatesGo to System Options Security Ieee Go to Setup System Options Security Certificates Basic TCP/IP SettingsDate & Time NetworkIPv6 Address Configuration IPv4 Address ConfigurationAssign IP Address Using ARP/Ping ARP/PingAxis Internet Dynamic DNS Service Advanced TCP/IP SettingsAxis Internet Dynamic DNS Service requires IPv4 DNS ConfigurationHost Name Configuration NTP ConfigurationLink-Local IPv4 Address NAT traversal port mapping for IPv4Smtp email QoS Quality of ServiceUPnPTM UPnPTM can be disabled under System Options Network UPnPTMRTP/H.264 BonjourSD Card StorageMount and Unmount SD Card Format SD CardPorts & Devices MaintenanceNetwork Share PortsSupport Overview SupportSystem Overview Logs & ReportsPlain Config Reset to Factory Default SettingsScripting File UploadAxis M3025-VE Network Camera Upgrade the Firmware TroubleshootingEmergency Recovery Procedure Check the FirmwareProblems setting the IP address Symptoms, Possible Causes and Remedial ActionsProduct cannot be accessed from a browser Product is accessible locally but not externallyVideo and image problems, general Problems with streaming H.264Video Camera Settings Key framesStorage and disk management problems Problem Retrieving Additional Video StreamsStorage disruption Re-mount the storage deviceTechnical Specifications Power Function/group Specifications System ApplicationConnectors DimensionsFunction/group Specifications Included ConnectorsConnector Function Pin SpecificationsPerformance Considerations M4.5