Axis Communications M3007-PV user manual Troubleshooting Emergency Recovery Procedure

Page 52

AXIS M3007–PV

Troubleshooting

Emergency Recovery Procedure

If power or network connection is lost during the upgrade, the process fails and the product becomes unresponsive. Flashing red Status indicator indicates a failed upgrade. To recover the product, follow the steps below. The serial number is found on the product’s label.

1.In UNIX/Linux, type the following from the command line:

arp -s <IP address> <serial number> temp ping -l 408 <IP address>

In Windows, type the following from a command/DOS prompt (this may require that you run the command prompt as an administrator):

arp -s <IP address> <serial number> ping -l 408 -t <IP address>

2.If the product does not reply in 30 seconds, restart it and wait for a reply. Press CTRL+C to stop Ping.

3.Open a browser and type in the product’s IP address. In the page that opens, use the Browse button to select the upgrade file to use. Then click Load to restart the upgrade process.

4.After the upgrade is complete (1–10 minutes), the product automatically restarts and shows a steady green on the Status indicator.

5.Reinstall the product, referring to the Installation Guide.

If the emergency recovery procedure does not get the product up and running again, contact Axis support at www.axis.com/techsup/

Symptoms, Possible Causes and Remedial Actions

Problems setting the IP address

When using ARP/Ping

Try the installation again. The IP address must be set within two minutes after power has been

 

applied to the product. Ensure the Ping length is set to 408. For instructions, see Assign IP Address

 

Using ARP/Ping, on page 42.

The product is located on a different subnet

The IP address is being used by another device

Possible IP address conflict with another device on the same subnet.

If the IP address intended for the product and the IP address of the computer used to access the product are located on different subnets, you will not be able to set the IP address. Contact your network administrator to obtain an IP address.

Disconnect the Axis product from the network. Run the Ping command (in a Command/DOS window, type ping and the IP address of the product):

If you receive: Reply from <IP address>: bytes=32; time=10...

this means that the IP address may already be in use by another device on the network. Obtain a new IP address from the network administrator and reinstall the product.

If you receive: Request timed out, this means that the IP address is available for use with the Axis product. Check all cabling and reinstall the product.

The static IP address in the Axis product is used before the DHCP server sets a dynamic address. This means that if the same default static IP address is also used by another device, there may be problems accessing the product.

The product cannot be accessed from a browser

Cannot log in

When HTTPS is enabled, ensure that the correct protocol (HTTP or HTTPS) is used when attempting

 

to log in. You may need to manually type http or https in the browser’s address field.

 

If the password for the user root is lost, the product must be reset to the factory default settings.

 

See Reset to Factory Default Settings, on page 50.

52

Image 52
Contents Axis M3007-PV About this Document LiabilityIntellectual Property Rights Equipment ModificationsSupport Learn MoreTable of Contents Axis M3007-PVConnectors and Buttons Network ConnectorHardware Overview Hardware OverviewLED Indicators SD Card SlotControl Button Color IndicationAccessing the Product Accessing the ProductAccess from a Browser Start a browser Internet Explorer, Firefox, SafariSet the Root Password Accessing the Product Access from the InternetClick Create self-signed certificate Live View Set Power Line FrequencyControls on the Live View Axis Media Control viewer toolbar PTZ ControlsHow to Stream H.264 Media StreamsMedia Streams Axis Media Control AMCAlternative Methods of Accessing the Video Stream QuickTimeTM. The following paths can be usedAxis M3007-PV Setting Up the Product Setting Up the ProductBasic Setup Video VideoVideo Stream Pixel CounterOverview View modesPanorama Double Panorama Quad ViewImage Click Save to apply the new settingsDirection 264 MjpegCamera Settings Stream ProfilesImage Appearance White BalanceExposure Settings View areasShutter & Gain Set Shutter toDate/Time Formats in the online help To enable overlays OverlayOverlay Image Go to Video Video Stream and select the Image tabPrivacy Mask Using Overlay Text in an Action RuleGo to Events Action Rules Live View Config Live View ConfigDefault Viewer for Browsers User Defined Links Viewer SettingsBrowser Viewer Description Preset Positions Go to PTZ Preset PositionsPTZ Pan Tilt Zoom PTZ Pan Tilt ZoomPTZ Pan Tilt Zoom Guard Tour AdvancedControls To add a guard tourDetectors DetectorsCamera Tampering Motion DetectionSet Up Motion Detection Windows Motion Detection ParametersGo to Detectors Motion Detection Parameter Object Size History Sensitivity DescriptionDefault values Medium level 50%Low level 0% Recommended valuesInstall Application ApplicationsApplications Application LicensesAxis M3007-PV Events EventsSetting Up an Action Rule RecipientsFallback Action Go to Events Action Rules and click AddRecipient Use with action Setting Up an Email RecipientGo to Events Recipients and click Add Events Schedules RecurrencesTo create a new schedule Go to Events Schedules and click AddRecordings RecordingsRecording List Continuous RecordingClick Save to save and start the recording Languages LanguagesSystem Options System OptionsSecurity UsersDate & Time IeeeCertificates CA CertificateBasic TCP/IP Settings NetworkAxis Internet Dynamic DNS Service Axis Internet Dynamic DNS Service requires IPv4Linux/Unix syntax Linux/Unix exampleAdvanced TCP/IP Settings DNS ConfigurationNTP Configuration Host Name ConfigurationNAT traversal port mapping for IPv4 FTPQoS Quality of Service UPnPTM can be disabled under System Options Network UPnPTMUPnPTM RTP/H.264Storage BonjourSD Card Network ShareMaintenance SupportSupport Overview To add a network shareSystem Overview Logs & ReportsScripting File UploadReset to Factory Default Settings Plain ConfigTroubleshooting TroubleshootingFirmware To upgrade the product’s firmware Checking the FirmwareTroubleshooting Emergency Recovery Procedure Symptoms, Possible Causes and Remedial ActionsProblems setting the IP address Product cannot be accessed from a browserProblems with streaming H.264 Product is accessible locally but not externallyBasic Video and image problems, general Video Camera SettingsStorage and disk management problems Key framesTechnical Specifications Technical SpecificationsFunction/group Specifications Maintenance Built-inInstallation aids Data Streaming PowerTechnical Specifications Performance Considerations Axis M3007-PV