Samsung SCC-C6323 Installation, DIP Switch Setup, Camera ID Setup, Communication Protocol Setup

Page 13

Installation

DIP SWITCH SETUP

Before you install the camera, you should set the DIP switches to confi gure the camera ID, Baud rate, and communication protocol.

Protocol

Buad Rate

Auto Select

 

RS-485

Terminate

ID Setting (1~255)

Camera ID Setup

ID number of camera is set using binary number. The example is shown bellow.

Pin

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

ID Value

1

2

4

8

16

32

64

128

 

 

 

 

 

 

 

 

 

ex) ID=5

on

off

on

off

off

off

off

off

ex) ID=10

off

on

off

on

off

off

off

off

 

 

 

 

 

 

 

 

 

The range of ID is 0~255. Factory default of Camera ID is 1.

If you want to control a certain camera, you must match the camera ID with Cam ID setting of DVR or Controller.

Communication Protocol Setup

ON ON

1 2 3 4 5 6 7 8

Select the appropriate Protocol with DIP switch combination.

 

Switch State

 

Protocol

 

 

 

 

Pin1

Pin2

Pin3

Pin4

 

 

 

 

 

 

OFF

OFF

OFF

OFF

Auto Protocol

ON

OFF

OFF

OFF

Pelco-D

OFF

ON

OFF

OFF

Pelco-P

ON

ON

OFF

OFF

Samsung

• If you set the protocol as Auto Protocol, camera

will automatically recognize the kind of Protocol.

• Auto Protocol supports Pelco-D and Samsung Protocol.

• If you want to control using DVR or system

 

keyboard, their protocol must be identical to

camera. Otherwise, you can not control the camera.

• If you changed camera protocol by changing DIP S/W,

the change will be effective after you reboot the camera.

• Factory default of protocol is “Auto Protocol

Communication Baud rate Setup

ENG

 

 

 

 

 

 

 

 

ON

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

Select the appropriate Baud rate with DIP switch combination.

 

Switch State

 

Protocol

 

 

 

 

 

Pin5

 

Pin6

 

Pin7

 

 

 

 

 

 

 

OFF

 

OFF

 

OFF

2400 BPS

ON

 

OFF

 

OFF

4800 BPS

OFF

 

ON

 

OFF

9600 BPS

ON

 

ON

 

OFF

19200 BPS

OFF

 

OFF

 

ON

38400 BPS

• Factory default of Baud rate is “9600 BPS”

English – 13

Image 13
Contents Please register your product at 10x Mini Smart Dome CameraSafety information ENG Important Safety Instructions Contents Motion Setup How to use OSD MenuDimension SpecificationsIntroduction FeaturesProduct & Accessories SCC-C6323 Product & AccessoriesProduct & Accessories SCC-C6325 Accessory ManualAccessory Product & Accessories SCC-C7325Terminal Block Torx Screw Driver Mount Bracket Option Wall Mount Bracket SADT-732WMParts Name & Functions DIP Switch Adjusts camera ID and protocols Cable DuctSCC-C6323 Main Unit / Surface Mount BracketMain Unit / Surface Mount Bracket Dome Cover SCC-C6325Back of Main Unit SCC-C7325 DIP Switch Setup InstallationCamera ID Setup Communication Protocol Setup① Setup DIP Switch see previous Installation Using Surface Mount on the CeilingRS-485 Termination Resistor Pin 8 RS-485 Termination Resistor On/Off⑤ Tighten locking screw Installation Using Ceiling Mount Bracket SCC-C7325 ④ Detach protection vinyl from dome cover Installation Using Wall Mount Bracket SCC-C732518 10X Mini Smart Dome Camera SCC-C6325/ SCC-C7325 CablingAlarm Input Connection Power ConnectionRS-485 Communication Video ConnectionReserved Preset Preset and Pattern Function PRE-CHECKOperation Auto CalibrationAuto PAN PresetPattern FunctionSchedule ScanOther Functions OSD Display of Main Screen SET Preset ×××Z Information Pattern ×Display Setup How to use OSD MenuGeneral Rules of KEY Operation for Menu Main MenuMotion Setup Privacy Zone Mask SetupPrivacy Zone Size Adjustment Privacy Zone Area SetupParking Action Setup Function SetupAlarm Input Setup Edit Preset Scene Preset SetupEdit Preset Label Auto PAN SetupScan Setup Pattern SetupEdit Pattern Edit ScanAction no NONE/PRESET/AUTO PAN/PATTERN ④ Set up items such as Action, NO., Dwell and OPTOPT Edit Schedule Schedule SetupWhite Balance Setup Camera SetupAuto Exposure Setup Relay Type Setup System SetupDATE/TIME Setup Password SetupHeater RUN Temp FAN RUN TempSET Home Position SET North DirectionInitial Configuration Table System InitializeFunction Data How to use OSD MenuSpecifi cations SpecificationsAppearance 768H´494V 380K SCC-C6325N/PCeiling Mount Wall Mount SCC-C7325N/PUnit mm DimensionWall Mount Bracket