Installation
❖Power Connection
•Please, check the voltage and current capacity of rated power carefully. Rated power is indicated in the back of main unit.
Power Mode | Input Voltage Range | Power Consumption | ||
C6323/ C6325 | C7325 | |||
|
| |||
|
|
|
| |
DC 12V | DC 11V ~ 15V | 8 W | 12W | |
|
|
|
| |
AC24V | AC 20V ~ 29V | 10W | 21W | |
|
|
|
|
❖RS-485 Communication
•For PTZ control, connect this line to keyboard and DVR. To control multiple cameras at the same time,
Keyboard Controller DVR
❖Video Connection
•Connect with BNC coaxial cable.
❖Alarm Input Connection
•Sensor Input
If you want to use Alarm Input, the types of sensor must be selected in OSD menu. The sensor types are Normal Open and Normal. If sensor type is not selected properly, the alarm can be activated reversely.
Normal Open | Sensor output is turned ON when |
(N.O) | sensor is activated |
INTERNAL
IN1
Normal Close | Sensor output is turned OFF when |
(N.C) | sensor is activated |
IN 2
IN COM
• Relay Output
Internal |
Relay Out |
Power |
Relay Out |
It is noted that short circuit between GND and Input pin means alarm activation.
There are 4 Alarm Outputs and all of them are Relay contact type. Therefore, you do not have to care about polarity, AC/DC, and isolations between channels. Care must be taken for the power capacity of relay contact written above.