3. PLOTTER OPERATION

3.11.8Alarm information

When an alarm setting has been violated, the buzzer sounds and the speaker icon appears and is red. Press the [CLEAR] key to silence the alarm. You can see which alarm has been violated on the ALARM menu. In the example below the arrival alarm has been violated.

1.Press the [ALARM] key. The name of the offending alarm appears in the alarm information window.

Alarm information window

AUDIO ALARM

INTERNAL BUZZ

ARRIVAL ALARM

ON 0.010nm

ANCHOR WATCH ALARM

OFF 0.010nm

PROXIMITY ALARM

OFF

XTE ALARM

OFF 0.050nm

SPEED ALARM

OFF

TRIP ALARM

OFF 0000.0nm

 

 

ALARM INFORMATION

ARRIVED

AT WAYPOINT XXX !

ALARM1

A EDIT

CCLEAR ALARM

DNEXT PAGE

E RETURN

Speaker icon

XXX = Destination waypoint name

Plotter alarm menu, page 1

2.Press the C:CLEAR ALARM soft key to acknowledge the alarm (and silence the buzzer if it was not done with the [CLEAR] key). The color of the speaker icon changes from red to background color. The icon remains on the screen until the cause of the alarm is eliminated or the alarm is disabled. If more than one alarm has been violated the message CONTINUE appears at the bottom of the alarm information window. In this case, press the B:NEXT INFO soft key to see which other alarms have been violated.

3.Press the [ALARM] key to finish.

Note: The alarm icon is red when an alarm setting is violated, and changes to background color when the [CLEAR] key or C:CLEAR ALARM soft key is pressed. The color does not change regardless of how many other alarms are violated.

3-58

offered by Busse-Yachtshop.de

Page 140
Image 140
Furuno 1943C-BB, FURUNO MARINE RADAR, 1953C-BB, 1933C-BB, 1823C-BB, 1833C-BB manual Alarm information, Plotter alarm menu