Samsung SCC-C6407(P) instruction manual Alarm SET, Other SET

Page 28

6. ALARM SET

It consists of 8 ALARM INPUTs and 3 ALARM OUTs.It can sense an ALARM input from exterior SENSORs and it performs with PRESET or PATTERN function and outputs the ALARM OUT signals.

The Alarm will be recognized only when its input lasts more than 150ms and the alarm operation time depends on the Preset Dwell time corresponding to the alarm and whether AUTO is involved.

AUTO SET

This menu designates what to do at the time of ALARM input. Once an alarm is given, the camera will shortly move to the PRESET position corresponding to the respective alarm as follows.

PRESET1 to ALARM1~8 PRESET9 to MOTION

After DWELL TIME at a PRESET position, PATTERN or SCAN will be in action according to the AUTO SET setup.

Setup of OFF/1/2/3/HALF1/HALF2/FULL/SCAN1~4 is available.

OFF dues not perform PATTERN or SCAN after moved to PRESET and each menu has its own function as follows.

E

* * MAIN MENU * *

CAMERA SET...

VIDEO SET...

PRESET...

ZONE SET...

AUTO SET...

ALARM SET...

OTHER SET...

SYSTEM INFO...

Press [Enter]

( ALARM SET)

ALARM PRIORITY SET ...

ALARM IN SET.. ALARM OUT SET.. AUTO SET..

AUX OUT CONTROL..

RET

PATTERN 1~3 : Preset PATTERN action,

HALF1 : Continuous operation of PATTERN1 + PATTERN2

HALF2 : Continuous operation of PATTERN2 + PATTERN3

FULL : Continuous operation of all the aboves

SCAN 1~4 : Scanning as set

AUX OUT CONTROL

This sets the ALARM OUT motion to continue or act only when the ALARM is working.

ALARM PRIORITY SET

This sets the priority of the 8 ALARM inputs so ALARM can work corresponding to the priority.

The priority of the DEFAULT is ALARM1, ALARM2, ALARM3, ALARM4, ALARM5, ALARM6, ALARM7, ALARM8.

If the ALARM is working at the same time and the priority is the same, it will operate according to the DEFAULT priority. While the ALARM is working, it cannot detect MOTION.

ALARM IN SET

This sets the input TYPE to "NO" (Normal Open), "NC" (Normal Close), or "OFF" depending on the features of the SENSOR connected.

ALARM OUT SET

Each ALARM input corresponds to one of the 3 ALARM OUT.

If it is set to OFF the ALARM OUT motion will operate only when the ALARM is working.

(Active "Low"), and if it's set to ON, the ALARM OUT will always operate regardless of the ALARM.

7. OTHER SET

PROPORTIONAL P/T

This function controls the PAN/TILT speed to the ZOOM magnification ratio during the manual operation of PAN/TILT. If you set PROPORTIONAL P/T to ON, the PAN/TILT speed will increase in the ZOOM WIDE mode and decrease in the ZOON TELE mode even in the same manual operation.

3-29

3-30

Image 28
Contents SCC C6407P Important Safety Instructions Safety PrecautionsFCC Statement Before Usage Table of contents Chapter CC-C6407 P Overvie wLocations of Control Adapter Connection Initial Setting Camera Address SetupCC- C6407P Installatio n Before Installing Ceiling Mount Bracket SBR-100DCM Wall Mount Adaptor SADT-100WMIndoor Housing SHG-120 Outdoor Housing SHG-220Ceiling Mount Adaptor SADT-100CM Pole Mount Adaptor SADT-100PMInstalling the Camera Setup Menu Overview Camera SET Menu Camera IDCOLOR/BW SyncAuto LevelMotion DET Zoom SpeedVideo SET Menu Digital ZoomExit IrisShutter ManuWDR AGC MotionWhite BAL AGC GainDIS Focus ModeDetail Preset Zone SET SET Zone Area SET ZoomReverse Zone DIR SET/ZONE Area SETZone Enable Zone DIR SETLocation Zone AreaAuto SET Auto Play ScanAuto Return Play NumberAlarm SET Other SETSystem Info Short Keys Function KeyProduct specifications SCC-C6407