Operating Your Camera
RESET
To reset your camera to factory default condition. (comm,language,monitor exception)
EXIT
To finish setup menu.
Troubleshooting
If you have trouble operating your camera, refer to the following table.
If the guidelines do not enable you to solve the problem, contact an authorized technician.
•Nothing appears on the screen.
▶Check that the power cord and line connection between the camera and monitor are fixed properly.
▶Check that you have properly connected VIDEO cable to the camera VIDEO output jack.
•The image on the screen is dim.
▶Is lens stained with dirt? Clean your lens with soft, clean cloth. ▶Set the monitor to proper condition.
▶If the camera is exposed to too strong light, change the camera position.
•The image on the screen is dark.
▶Adjust the contrast feature of the monitor.
▶If you have an intermediate device, set the 75Ω /
•The camera is not working properly, and the surface of the camera is hot.
▶Check that you have properly connected the camera to an appropriate power source.
•The SENS-UP function does not work.
▶Check that AGC of EXPOSURE SETUP menu is ‘OFF’.
▶Check that SHUTTER of EXPOSURE SETUP menu is ‘A.FLK’ or ‘MANUAL’.
•The Motion Detection function does not work.
▶Check that MOTION DET of SPECIAL SETUP menu is ‘OFF’.
•Color is not correct.
▶Check the setting of WHITE BAL SETUP menu .
•The screen flickers continually.
▶Check that direction of camera turns toward the Sun.
•When coaxial communication is not available:
▶Make sure that the camera and monitor are installed within the recommended distance. ▶Use the video amplifier equivalent to coaxitron if the recommended installation distance
is exceeded.
•IR-LED isn't lighted.
▶Isn't DAYNIGHT function setting up the color mode. ▶Please change the AUTO or B/W mode.
COLOR CCD CAMERA 40 User Guide | COLOR CCD CAMERA 41 User Guide |