Kenwood XD-9581MD instruction manual MD recorder section other symptoms, Symptom Cause

Page 80

80

Preparation section

Basic section

Application section

Knowledge sections

 

 

 

 

 

In case of difficulty

 

 

 

 

 

XD-9581MD (En)

Symptoms related to MD standard

 

 

 

 

 

 

 

 

 

 

 

 

Symptom

 

 

 

Cause

 

 

 

 

 

“DISC FULL” is displayed while the disc still has a remaining re-

ÖMore than 255 tracks (track No. 256 or more) cannot be recorded. (There

cordable time.

 

may be also cases in which recording is impossible while the track

 

 

 

number is less than 256.)

 

 

 

 

In such a case, the REMAIN time display shows “0:00”.

 

 

 

 

 

The possible recording time does not increase even when a short

ÖWhen the remaining time of the entire disc is less than 12 sec, the

track is erased.

 

remaining time indication on the display becomes “0:00”. When the

 

 

 

total time of the deleted tracks exceeds 12 sec, the display changes to

 

 

 

the recordable time.

 

 

 

 

 

ÖWhen a short track is deleted on a repeatedly edited disc, the remaining

 

 

 

time may not increase.

 

 

 

 

 

 

 

Tracks can not be connected.

 

ÖConnection of the track resulting from edit processing may not be

 

 

 

possible.

 

 

 

 

 

 

The time which has been recorded on the MD and the remaining

ÖAs recording is executed with 2 sec. as the minimum unit, the display

time do not add up to the maximum recording time (60 or 74 min.).

time may not coincide.

 

 

 

 

 

 

When search is performed in a track which has been compiled by

ÖThis derives from the restriction in the MD system standard and not a

editing, the sound is sometimes interrupted.

 

malfunction.

 

 

 

 

 

 

The track numbers are not assigned correctly.

ÖDepending on the contents of the recorded source (CD etc.), the track

 

 

 

numbers may not be assigned correctly.

 

 

 

 

ÖThe track number may be increased in case of dirt or scratches on the CD.

 

 

 

 

“DISC READING” is displayed for an abnormally long time.

ÖWhen a new recordable MD (with nothing recorded) is inserted,

 

 

 

“DISC READING” is displayed longer than usual.

 

 

 

 

 

The time display becomes inaccurate with a monaurally recorded

ÖMonaural recording and stereo recording are executed according to

disc.

 

different formats. This is not a malfunction.

 

 

 

 

 

 

Input of 1792 title characters is not possible.

 

ÖThe title recording area is used in units of 7 characters, so that input of

 

 

 

1792 characters may not be possible.

 

 

 

 

 

 

 

MD recorder section (other symptoms)

 

 

 

 

 

 

 

 

 

 

Symptom

 

Cause

 

Remedy

 

 

 

 

 

 

 

Sound is not output even when the play key

 

ÖThe cords are connected erroneously.

 

ÖConnect the cords in accordance with

6

is pressed.

 

 

 

 

“System connections”.

 

 

ÖNo disc has been loaded.

 

ÖLoad a disc.

ª

 

 

ÖA non-recorded disc has been loaded.

 

ÖLoad a prerecorded disc or playback-

j

 

 

 

 

 

only disc.

 

 

 

 

 

 

Recording is not possible

 

ÖThe disc is write-protected.

 

ÖChange the position of the write pro-

 

 

 

 

 

 

tect tab to the write position or use a

5

 

 

 

 

 

recordable disc.

 

 

ÖAn attempt is made to record digital signal from

 

ÖRecording is not possible.

k

 

 

a source while its digital copy has been prohib-

 

 

 

 

 

ited by SCMS.

 

 

 

ö

 

 

ÖThe recording level is too low. (with use of AUX

 

ÖAdjust the input level.

 

 

or TAPE)

 

 

 

j

 

 

ÖA playback-only disc has been loaded.

 

ÖUse a recordable disc.

 

 

ÖThe disc does not have a recordable area.

 

ÖUse another disc.

°

 

 

ÖThe input selector is set to MD.

 

ÖSet the input selector to the source to

¥

 

 

 

 

 

be recorded.

 

 

 

 

 

 

Sound is distorted.

 

ÖThe recording level has not been adjusted(with

 

ÖAdjust the input level.

ö

 

 

use of AUX or TAPE).

 

 

 

¥

 

 

ÖA disc in which distorted sound has been re-

 

ÖRecord again.

 

 

corded is played.

 

 

 

 

 

 

 

 

 

 

Noise is noticeable.

 

ÖAn external noise is induced.

 

ÖInstall the unit at a position apart from

 

 

 

 

 

 

an electric appliance or TV set.

 

 

 

 

 

 

 

The recorded volume changes during the

 

ÖThe jog dial has been moved during analog

 

ÖDo not move the knobs during record-

¥

recording.

 

recording.

 

 

ing.

 

 

 

 

 

 

The display goes out for a moment after the

 

ÖSwitching is operated too quickly.

 

ÖThis is not a malfunction.

 

unit has been turned ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 80
Contents XD-9581MD Before applying power Safety precautionsMarking of products using lasers Except for some areas For the United KingdomContents Knowledge sectionSpecial features An MD recorder is standard equipment Versatile tone and sound field adjustmentConvenient timer functions Sampling FrequenciesHandling of Mini Disc Disc handling precautionsHandling of discs System connection Speaker left Speaker Section Speaker cordDigital output terminal Digital input terminalBeforeSystemapplyingconnectionpower Super-Woofer OperationSuper woofer SW-500 optional FM outdoor antennaCassette deck X-H9 optional Audio cordSystem control cable Optical Optical Digital input terminalControls and indicators Tuner/equalizer sectionSpectrum analyzer display Controls and indicatorsDisplay Tuner/equalizer section Amplifier section 1ON/STANDBYCD player section MD recorder section Display MD recorder section Peak level meter displayRemote control unit Operation of remote control unit Loading batteriesOperation Remove the cover Insert batteries Close the coverLets put out some sound Basic use methodMuting the sound temporarily only on the remote control Listening through headphonesAuto Power Save function Standby modePlayback of CD Lets put out some soundSkipping tracks Playback from desired trackTo fast forward and backward To pause playbackPlayback of Mini Disc Disc recorded in monaural mode Searching in a trackTo pause playback To stop playback Regard to display scrollingConfirm that the PGM indicator is not lit Regard to automatic title searchPress the Title Search key Select the desired titleRegard to the Time Display key Regard to Display keyElapsed time of track being played Peak level meter independent L and R indicationReceiving broadcast station Select the tuning mode Collective presetting of stations auto presetOne-by-one presetting manual preset Lets record Recording on MDAUX TapeAlways remove the minidisc after recording Pause the recordingStop the recording Regard to display messages Tips for recording from a CD How to use the REC Input keyHow to use the AUTO/MANU. Key Playback of CD Listening in the desired sequence program playbackTo quit the program mode To check the programmed tracksTo add a track to the program 1Select the discRepeated playback To stop repeated playbackConfirm that the PGM indicator is not lit Select the Random modePress so that the Random indicator goes off Please select the disc before selecting1Let the PGM indicator light Playback of MDStart playback @ 0 0Checking the order of tracks To clear tracks from the programClearing tracks from the end Clearing all tracksDesired sequence Let the Repeat indicator light Press the Repeat key againPlayback of MD To switch the display contents S. Radio Data System2Select the desired program type Select the PTY search modeSearching for a desired program type PTY search When a station is received Start the searchTo change to a different program type Repeat steps 1, 2Auto preset the stations Select a station where RDS and EON are litSelect the desired information Receive an RDS stationRegard to TP Traffic Program indicator Wait for the desired informationConvenient recording methods Selection of the recording typeConvenient function Convenient recording methodsWhen a desired track is found, only that track is recorded Fade-in/fade-outOne-touch recording of one CD, MD Recording of one CD or several CDs CD =MD p CD =TAPE QTo interrupt a recording Make the preparations for recordingStart recording Press during playback Playback of a CD or MDAt the end of the recording Twin Recording Function Press the Twin REC keyProducing an MD or a tape collecting only the first titles Press the Best Hits key4Start edit recording Select the discWithin 8 seconds Repeat key is not effectiveTo check the edited contents To clear the edited contents Recording of one CD or several CDs CD =TAPE3Start edit recording To stepMake sure that the PGM indicator is off Light the Edit indicatorEnter the disc and tape conditions Start edit recordingAutomatic Space Function To check the edited contentsTo clear the edited contents Select the disc Make sure that the PGMindicator is offFade-out/Fade-in at the tape reversal CD =TAPE only MD edit functions Dividing a track, combining two tracksErasing tracks MD edit functionsActivate the title input mode Assigning a title to a disc or trackInput the title Execute title assignmentChanging or deleting a title Total number of title charactersExecute title change or deletion Character Track EditMoving several tracks at a time Quick Move 1Select Q.MOVE2Select the range of tracks to be reordered Execute the track move operationMoving a single track Track Move Select MoveSelect the track to be moved Select the moving destination trackDividing a track Track Divide Play the track to be dividedDivide ? Preview functionExecute the track divide operation After editing, eject and remove the mini discTitle division image Disc Writing displayed during the mini disc ejectionCombining two tracks Track Combine Select Combine2Select the track to be combined Execute the track combine operationErasing several tracks at a time Quick Erase 1Select Q.ERASESelect the titles to be erased Execute the erase operation2Select the Erase mode Make the preparations To erase one track Track EraseTo erase all tracks ALL Erase Track Erase ALL EraseExecute Track Erase Once Erasing a part of a trackTrack Divide P Enjoying sound field effects Switch on SRS 3DAdjust the effect strength level Listening with the desired sound equalizer function Equalizer frequency band adjustmentEffective sound field and sound quality adjustment Select balance adjustment 2AdjustSelect Tape adjustment or AUX ad- justment AdjustSwitching the spectrum analyzer display Multi-function display switching demonstration functionSwitching the superposed display Clock adjustment Activate the clock adjustment mode2Enter the figure of hour 3Enter the figure of minuteTimer operation Operate easy To use Timer O.T.TSleep timer To cancel4Select a program No 2Adjust the listening volumeMake preparations for the play recording Select the timer program No. to be used Enter the on timeEnter the OFF Standby time Make the desired reservationCheck the reservation content To change the reserved contentsWhen timer operation is not required To set the same timer program againAdjust the clock before setting the timer Maintenance Maintenance of the SetRegard to contact cleaners Important itemsMD system CaseImportantof difficultyItemsScms Serial Copy Management System Digital recording and ScmsDigital copy can- not be repeated Operation to reset Symptom Cause RemedyCase of difficulty Amplifier section/SpeakersMD recorder section other symptoms Symptom CauseDisc Error No DiscTitle Full Blank DiscRemote control unit CD player sectionSpecifications Tuner/equalizar unit C-H7 / Amplifier unit A-H5For your records CD player unit DP-MH5Speakers LS-J6