Reduces power consumption
• POWER SAVE: | When this function is turned ON, luminous level of the Plasma Display is suppressed, so |
| power consumption is reduced. |
• STANDBY SAVE: | When this function is turned ON, power consumption of the microcomputer is reduced during |
| power supply standby (see page 12, 14, 15), so standby power of the set is reduced. |
• POWER MANAGEMENT: | When this function is set to ON, it operates under the following conditions to turn the power |
| on or off automatically. |
| When no pictures (sync signals) are detected for 30 or so seconds during PC IN signal |
| input: |
| →Power is turned off (standby); the power indicator lights up orange. |
| The power is not turned off when the SYNC ON G sync signal has been detected. |
| When pictures (sync signals) are subsequently detected: |
| →Power is turned on; the power indicator lights up green. |
| The power is not turned on when only the SYNC ON G sync signal has been |
| detected. |
| Notes: |
| • This function operates only during PC IN signal input. |
| • This function is invalid during input from PC Input Terminal Board |
| • This function is effective when “SYNC” is set to “AUTO”, “COMPONENT / |
| is set to “RGB” and during normal viewing (one picture screen). |
• AUTO POWER OFF: | Equipment power supply is turned OFF when there is no signal. |
| When this is set to On, the power supply of the unit goes Off 10 minutes after the input |
| signals stop. |
| Notes: |
| • This function operates only during PC IN signal input. |
| • This function is effective when “SYNC” is set to “AUTO”, “COMPONENT / |
| is set to “RGB” and during normal viewing (one picture screen). |
1
2
Press to select
“POWER SAVE”
“STANDBY SAVE” “POWER MANAGEMENT” “AUTO POWER OFF”.
Press to select “ON” or “OFF”.
On Off
SET UP | 1/2 |
SIGNAL |
|
SCREENSAVER |
|
INPUT LABEL | RGB |
PC | |
POWER SAVE | OFF |
STANDBY SAVE | OFF |
POWER MANAGEMENT | OFF |
AUTO POWER OFF | OFF |
OSD LANGUAGE | ENGLISH (US) |
3 Press to exit from SET UP.
28