Panasonic TH37PR11UK operating instructions Normalization

Page 37

Options Adjustments

Item

 

 

 

 

Adjustments

 

Off

1

2

3....

30

 

You can set the power-on delay time of the displays to reduce the power load, when you press POWER switch

 

to turn on the multiple displays that are set together.

 

Set each display’s setting individually.

 

Off:

 

The display will be turned on at the same time as POWER switch is pressed.

 

1 to 30 (sec.): Set the power-on delay time (second).

 

 

 

After pressing POWER switch, the display will be powered on with time delay depending on this

Power On Screen

Notes:

 

setting.

 

 

 

 

 

Delay

• During this function is working, the power indicator is blinking green.

This function also works when the power recovers from failure or after plugging off and in again the power cord.

After you unplug and plug the power cord in while the unit is in standby mode and also the power is being supplied to a terminal board, the unit will start supplying the power to the board with time delay according to the setting.

The power indicator lights up red first and it turns orange when the power starts being supplied to the board.

Off: Not display the clock.

On: Display the clock.

The clock is displayed at the lower left of the screen when button is pressed.

Clock Display

1 0 : 0 0

Note: When “PRESENT TIME SETUP” is not set, the clock is not displayed even if “Clock Display” is “On” (see page 25)

 

Sets All Aspect mode (advanced aspect setting) or default aspect mode.

 

With each press of

button, the aspect changes in the selected mode.

 

Off:

Default aspect mode

All Aspect

On:

All Aspect mode

Aspect mode of each setting is as follows:

 

 

(Example: HD signal)

 

 

Off 4:3→H-FILL→ZOOM→FULL→JUST

 

On 4:3 (1)→4:3 (2)→4:3 Full→Zoom1→Zoom2→Zoom3→16:9→14:9→Just1→Just2

Serial Slot

Slot1

Slot2

Slot3

Selects the slot which communicates serial.

Select

Note: The setting of an external command can be set only from the fixed serial terminal. (see page 11)

 

Normalization

When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again.

Press the

button on main unit together with

button on the remote control and hold for more than 5 seconds. The

“SHIPPING” menu is displayed and the lock is released when it disappears.

37

Image 37
Contents English Español Operating Instructions Manual de instruccionesModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents Canadian Notice FCC CautionTrademark Credits When using the Plasma Display Safety PrecautionsSetup MaintenanceAC Power Supply Cord If problems occur during useAccessories Supplied AccessoriesCheck that you have the Accessories and items shown AC cord fixing ConnectionsCable fixing band PC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorCommand Signal names for D-sub 9P connectorSerial Terminals connection Communication parametersConnecting the AC cord plug to the Plasma Display Power on / OFFConnecting the plug to the Wall Outlet Initial selections Selecting the input signalSelecting the On-Screen Menu Language INPUT1 INPUT2 INPUT3 PCBasic Controls On OFF Aspect Controls All Aspect modePanasonic Auto Multi PIP Advanced PIP Display the operation guide Digital ZoomPosition Select the magnification required for the enlarged displayOn-Screen Menu Display Adjusting POS. /SIZE Standard Picture AdjustmentsDynamic CinemaAdvanced Settings Press to exit from adjust mode Sound AdjustmentSET UP Timer Present Time SetupPresent Time Setup Start setting Setup of Screensaver TimeScreensaver For preventing image retention Function selectionReduces screen image retention Side BAR AdjustOFF Dark MID Bright Reduces power consumption INPUT3/VIDEO3/COMPONENT3/RGB3/PC3/DVD3/CATV3/VCR3/STB3 Customizing the Input labelsPC/COMPONENT/RGB/DVD/STB Addition sign Selected InputComponent / RGB in Select SET UP for Input SignalsYUV / RGB in Select When ON, this setting only affects Ntsc input signals Signal menu3D Y/C Filter For Ntsc AV images For ComponentMode Function XGA ModeColor System / Panasonic Auto PulldownRefresh Rate Press to adjustNoise Reduction Advanced NRSetting RGB sync signal Input signal displaySync Press to adjust the menu Press to exit from Options menu Options AdjustmentsOptions Adjustments Normalization Press Action button Weekly Command TimerProgram number Program Edit screenTime Set the time to execute a command program Press to select Time / CommandShipping condition Press to set each itemPlasma Display panel TroubleshootingFull List of Aspect ModesRGB PC input signalsCommand list of Weekly Command Timer TH-37PR11UK/H TH-42PR11UK/H SpecificationsFor the U.S.A Panasonic Professional Flat Panel Display Limited WarrantyFor Canada Limited Warranty StatementPage Page Page Panasonic Professional Display Company Customer’s RecordExecutive Office Panasonic Canada Inc