Options Adjustments
Item |
|
|
|
| Adjustments | |
| Off | PC | INPUT1 | INPUT2 | INPUT3 | |
| Locks the input switch operation. |
| ||||
| Notes: |
|
|
|
| |
| • Only the adjusted signal is displayed (see page 13). | |||||
INPUT lock | • Signal can be displayed when the Terminal board is installed. | |||||
• Input switch can be used when this is set to “Off”. | ||||||
|
•In two screen display mode, if anything other than “Off” is set, the value will be fixed as the value input in the single screen display mode.
•When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B)
Off MENU&ENTER On
Off: All the buttons on main unit can be used.
MENU&ENTER: Locks and buttons on main unit.
|
|
|
| MENU |
| ENTER/ |
|
|
|
|
|
Button lock | On: Locks all the button on main unit. |
|
|
|
| ||||||
Sets Button lock with the unit buttons in the following procedure. |
|
| |||||||||
| Off: Press | four times→Press | four times→Press | four times→Press |
| ||||||
| MENU&ENTER: Press |
| INPUT |
| four times→Press | ENTER/ |
| ||||
| four times→Press | four times→Press |
| ||||||||
| On: Press |
| ENTER/ |
|
| four times→Press | INPUT |
| ENTER/ | ||
| four times→Press | four times→Press |
| ||||||||
|
|
|
|
|
| ENTER/ |
|
|
| ENTER/ |
|
| Off | User1 | User2 | User3 |
|
|
|
| |||
| Off: | You can use all of the buttons on the remote control. |
|
| |||||||
Remocon User level | User1:You can only use | , | , , | , , | buttons on the remote control. |
|
User2:You can only use button on the remote control.
User3:Locks all the buttons on remote control.
| Off: | Sets normal two screen display mode (see page 17). | ||||
| On: | Sets Advanced PIP mode (see page 18). | ||||
Advanced PIP | Notes: |
|
|
|
| |
| • When “INPUT lock” is “On”, you cannot use all the two screen display functions. | |||||
| • , | buttons are unavailable during Advanced PIP mode operation. | ||||
|
|
| ||||
| Enable: | Enables the | ||||
Disable: | Disables the | |||||
| Note: |
| When “Disable” is set, the | |||
| Normal | Standby | On | |||
| Sets the power mode of the unit for when the power recovers from failure or after plugging off and in again. | |||||
Initial Power Mode | Normal: Power returns in as the same state as before the power interruption. | |||||
Standby: Power returns in standby mode. (Power Indicator : red/orange) | ||||||
| ||||||
| On: |
| Power returns in power On. (Power Indicator : green) | |||
| Note: |
| When using multiple displays, “Standby” is preferred to be set in order to reduce a power load. | |||
| Sets panel ID number when panel is used in “Remote ID” or “Serial ID”. | |||||
ID select | Set value range: 0 - 100 |
| ||||
| (Standard value: 0) |
|
| |||
| The setting of this menu is valid only when using ID remote control. | |||||
Remote ID | Off: | Disables ID remote control functions. You can use normal remote control operations. | ||||
| On: | Enable ID remote control functions. | ||||
| Sets the panel ID Control. |
| ||||
Serial ID | Off: | Disables external control by the ID. | ||||
| On: | Enables the external control by the ID. | ||||
| Off |
| Auto | On |
| |
| Off: | Power is not transmitted to the slot power. | ||||
Slot Power | Auto: Power is transmitted to the slot power only when main power is on. | |||||
On: | Power is transmitted to the slot power when main power is on or in the standby state. | |||||
| ||||||
| Note: In some cases, power is transmitted to the slot power when main power is on or in the standby state | |||||
|
| regardless of the slot power setting. |
36