Sharp PN-V602 Remote Control Mode, 21 E, This Monitor only, Specified Monitor, ALL Monitors

Page 21

Remote Control Mode

With the remote control unit it’s possible to perform operation

of...

The primary monitor

Monitors with a specified ID No.

All primary/secondary monitors

It’s necessary to specify which type of operation will be performed in advance.

1.If using the remote control unit, press MODE for approx 5 seconds.

If using the monitor buttons, hold both and at the same time on the primary.

REMOTE CONTROL MODE

MODE

▲ THIS MONITOR ONLY▲

Operate this monitor.

OK CANCEL

2. Press or , select the mode, then perform settings.

THIS MONITOR ONLY

Performs operation of only the primary using the remote control unit.

[Example] If the volume is lowered, the volume of the primary will lower.

Secondary

 

Primary

ID No.: 2

 

ID No.: 1

 

 

VOLUME 10

 

 

 

 

 

Secondary

 

Secondary

ID No.: 3

 

ID No.: 4

 

 

 

 

Press to lower the volume

SPECIFIED MONITOR

Performs operation of a monitor with a specified ID No. using the remote control unit.

Press or to select ID No., then press or to select the ID No. of the monitor that you will operate.

*When it receives signals from the remote control unit, “Operating specified monitor.” will be displayed on the

primary screen.

[Example.] If ID No. is set to 3 and the volume is lowered, the volume of the monitor for ID No.: 3 will lower.

 

Secondary

Primary

 

ID No.: 2

ID No.: 1

 

 

 

 

 

Secondary

Secondary

 

ID No.: 3

ID No.: 4

 

VOLUME 10

 

 

 

 

 

 

Press to lower the volume

When you would like to confirm the ID No. that is set to the

monitor, press or to select ID No. DISPLAY, then press . The ID No. will be displayed on the screen.

ALL MONITORS

Performs operation of all primary/secondary monitors.

*ALL will be displayed on the menu of the primary.

*When it receives signals from the remote control unit,

“Operating all monitors.” will be displayed on the secondary screen. (Excluding power and input mode selection operation)

*Settings may not be reflected depending on the state of the connected monitors.

[Example] If the power for the primary is turned ON, the power for all the monitors will be turned ON.

 

 

Secondary

Primary

 

 

 

ID No.: 2

ID No.: 1

 

 

 

Power ON

Power ON

 

 

 

Secondary

Secondary

 

 

 

ID No.: 3

ID No.: 4

 

 

 

Power ON

Power ON

 

 

 

Press POWER to turn the power ON

 

Press

or

to select EXPAND ITEM, and press

or

to select to perform this action or not.

OFF ...........For all monitors, only power, input mode

selection, and product information display operations will be recognized.

ON .............For all monitors, all operations will be

recognized.

After returning to the normal screen with procedure 3, when 5 minutes have passed from the end of operation, it will automatically return to OFF.

ALL [EXPAND ITEM] will be displayed on the menu of the primary.

*Even when REMOTE CONTROL MODE is set to ALL MONITORS, certain settings such as

LAN settings and ID No. settings will not be reflected on the other monitors.

3.Press or to select OK, then press MENU and return to the normal screen.

4.Perform operation.

Caution

When the remote control mode is set to ALL MONITORS and EXPAND ITEM is set to ON, performing remote control operations that change adjustment values will result in the secondary adjustment values being the same as the primary adjustment values.

Secondary

Primary

Secondary

Primary

ID No.: 2

ID No.: 1

ID No.: 2

ID No.: 1

VOLUME 12

VOLUME 11

VOLUME 10

VOLUME 10

Secondary

Secondary

Secondary

Secondary

ID No.: 3

ID No.: 4

ID No.: 3

ID No.: 4

VOLUME 9

VOLUME 10

VOLUME 10

VOLUME 10

Press to lower the volume

Be careful of this when adjusting individual displays.

TIPS

You can copy the setting values of the primary to other monitors with COPY SETTING VALUE. (See page 25.)

The buttons on the monitor itself (primary) are also effective in remote control mode.

When monitors connected in a daisy chain are in standby mode for LOW POWER, operation cannot be performed for subsequent monitors.

21 E

Image 21
Contents PN-V602 GREEN-AND-YELLOW For Customers in U.KBlue BrownImportant Information Refer Servicing to Qualified Service PersonnelInformation on Disposal for Business Users Information on Disposal for Users private householdsEuropean Union Other Countries outside the EUDear Sharp Customer Safety Precautions Use only the power cord supplied with the monitor Rear side buttons Remote control unit buttonsFan in this product has a limited lifetime Mounting Precautions Supplied Components ContentsPart Names NFront viewNRear view 11 E Connection when the PN-ZB02 optional is attached Connecting Peripheral Equipment13 E Connecting Peripheral EquipmentMultiple monitor connection Connection with video cableConnection with the control kit optional Connect the monitors in orderSet the ID No Connecting the Power Cord Preparing the Remote Control UnitInstalling the batteries Remote control operation rangeRemoving the Handles Binding CablesAffixing the Protection Covers Be sure the handles are attached securelyTurning on the main power Turning Power On/OffTurning power on/off Disabling power on/off operationsVOL +/- Volume adjustment Input Input mode selectionBasic Operation Mute19 E Basic OperationDisplay Wide Zoom Normal Basic Operation NSwitching the screen sizeDot by Dot Cut off21 E Remote Control ModeThis Monitor only Specified MonitorDisplaying the menu screen Menu ItemsNExample of operation NMenu screen displayMenu item details 23 ENSCREEN Menu Items NPICTURENSETUP Menu ItemsNAUDIO 25 E Menu Items NOPTION 27 E NMULTIMenu Items NPIP/PbyP Menu Items NDual screen display NEnlargePIP NZOOM2 Special Setting 29 ENSCHEDULE Adjustments for PC screen display NAutomatic adjustmentNScreen display for adjustment 31 E Controlling the Monitor with a PC RS-232C Communication procedurePC connection Communication conditionsNCommunication interval 33 EControlling the Monitor with a PC RS-232C NCommands for ID controlNID numbers Advanced operationNRepeater control 35 EVOLM0020 ← OK 002 IDLK0000 ← Wait ← OK 002 ← VOLM0010 OK 001 ←NTo transfer the Gamma user data Setting of the Gamma user dataNSaving the Gamma user data NActivating the Gamma user dataPower control/Input mode selection RS-232C command tableHow to read the command table 37 EControlling the Monitor with a PC RS-232C Screen menu Controlling the Monitor with a PC RS-232C Picture menu 39 EControlling the Monitor with a PC RS-232C Audio menu Setup menuControlling the Monitor with a PC RS-232C Option menu 41 EImage Position Epos setting Controlling the Monitor with a PC RS-232C Multi menuHorizontal orientation Vertical orientation Initialization/Functional Restriction Setting Function menu 43 EControlling the Monitor with a PC RS-232C PIP/PbyP menu Controlling the Monitor with a PC RS-232C Others Commands for setting of the Gamma user dataControlling the Monitor with a PC LAN Settings to connect to a LAN45 E To set on the monitorControlling the Monitor with a PC LAN To set from a PC Default Gateway 0.047 E Controlling with a PCControlling the Monitor with a PC LAN Information about this monitor appears Standby mode, Power on is the operation available49 E User Name / PasswordDNS Server Accept IP AddressAuthentication Installation Information NAME/LOCATIONAccount Name / Password Monitor NameRecipient E-MAIL Addresses 51 ECondition ConfirmationTrap Setting Snmp SettingTrap Setting of Authentication Error Version53 E TroubleshootingTroubleshooting NPN-V602 Product Specifications SpecificationsNPN-ZR01 optional Product Specifications 55 ENPower management Specifications NDimensional DrawingsNPOWER Limited See Set to ensure maximum power consumption. See57 E Specifications NCompatible signal timing PCSpecifications NCompatible signal timing AV 59 E PN-V602 Me EN11H1
Related manuals
Manual 28 pages 8.65 Kb Manual 60 pages 23.69 Kb