Bosch Appliances PLE-2MA120-EU manual Mechanical, Environmental

Page 32

Plena Mixer Amplifier Installation and User Instructions Technical data

en 32

6.1.7Music inputs 3x

Connector

Cinch, stereo converted to mono

Sensitivity

200mV

Impedance

22kohm

S/N (flat at max volume) >70 dB

S/N (flat at min volume/muted) >75 dB

Headroom >25 dB

6.1.8Emergency / telephone 1 x

Connector

7-pin, Euro style pluggable screw terminal Sensitivity tel

100 mV – 1 V adjustable Sensitivity 100V

10 V – 100 V adjustable Impedance

>10 kohm

S/N (flat at max volume) >65 dB

VOX

threshold 50 mV; attack time 150 ms; release time 2 s

6.1.9Loop through insert 1 x

Connector

Cinch

Nominal level

1V Impedance >10 kohm

6.1.10 Master/music output 1 x

Connector

3-pin XLR, balanced Nominal level

1V Impedance <100 ohm

6.1.11Loudspeaker outputs 100 V*

Connector

Screw, floating

Max / rated PLE-2MA120-EU 180 W / 120 W

Max / rated PLE-1906/10 360 W / 240 W

6.1.12 Loudspeaker output 8 ohm*

Connector

Euro style pluggable screw terminal, floating

PLE-2MA120-EU 31 V (120 W) PLE-2MA240-EU 44 V (240 W)

* Subtract 1 dB for 24 V battery operation.

6.2Mechanical

Dimensions (H x W x D)

100 x 430 x 270 mm (19" wide, 2U high) Mounting

Stand-alone, 19" rack

Color

Charcoal

Weight (PLE-2MA120-EU)

Approx. 10.5 kg

Weight (PLE-2MA240-EU)

Approx. 12.5 kg

6.3Environmental

Operating temperature -10 to +55 ºC Storage temperature -40 to +70 ºC Relative humidity <95%

Acoustic noise level of fan

<33 dB SPL @ 1 m temperature control

Bosch Security Systems 2007-11 PLE-1MA030-EU, PLE-1MA060-EU, PLE-1MA120-EU en

Image 32
Contents Plena Mixer Amplifier Important safeguards Table of contents Operation Introduction PurposeDigital document Intended audience Related documentationConversion tables Conversion of units of massContents of box DescriptionPlena product range Plena Mixer AmplifierSchematic overview of the Plena Mixer Amplifier Plena PLE-WP2Z3S wall panel Controls, connectors and indicatorsFront panel Rear panel Rear panel Intentionally left blank Installation Install unit in rack optionalCheck settings/connections Unpack unitIntentionally left blank DC supply battery Connections and settingsConnecting inputs XLR connector only Priority microphone inputSecondary microphone input Additional microphones inputs 3 throughConnecting 100 Volt input signal Emergency inputsConnecting emergency telephone lines Connecting music source inputs Music source inputsConnecting outputs Zone 1Call only Music onlyConnecting speakers Constant voltage loudspeakersUnit settings Rear panel settingsRotary controls Pin settings and labelling Intentionally left blank Switch on and off Switch offSwitch on OperationTone control Microphone/line controlsMusic controls Zone selection Master volume controlOutput controls Intentionally left blank Technical data ElectricalMechanical EnvironmentalPage For more information visit