Crimestopper Security Products CS-2014DP-TW2 manual Diesel Glow Plug Delay, Programmable Options

Page 18

DIESEL GLOW PLUG DELAY

This feature provides a solution for diesel vehicles without having to connect to the Glow Plug-“Wait to Start Circuit” input. This may be due to a variety of reasons for example: If your vehicle does not have a viable “Wait to Start Circuit” or you cannot locate and identify the circuit. You can choose from a selection of “pre-cranking” delay times. Once this mode is activated, the system will NO LONGER monitor the PINK glow plug input wire and will use a delay setting chosen by the installer in the option chart.

NOTES: This feature is OFF by default and must be programmed before use. Once this feature is turned ON, the Pink Glow plug input wire is not used. The Remote start unit will always wait the programmed time before cranking EVEN IF the glow plugs warm up first. There are 3 different Delay times available for use: 10, 20, or 30 seconds. SEE PROGRAMMING OPTION CHART, next section.

HOW TO USE THIS FEATURE:

1.See the “Programmable Options” next section and change Option #22 from "Monitor Glow Plug Light" to one of the delayed time values. (Default setting is to always monitor the PINK Glow Plug input wire.)

2.Once this option has changed the system will wait for the selected time before cranking the engine.

PROGRAMMABLE OPTIONS

You can program multiple options in one session if you start with the lowest option and continue on to higher options [if needed] without repeating steps #1-3 below. For example, you can follow the programming steps to change Option #2 to “OFF” by pressing the lock button on the remote, then you can continue pressing the program button additional times to get to a high number option and change the setting without having to repeat Steps 1-5. You can only go from low to higher option numbers in one session.

To Engage Option Programming:

1.Open Hood (ground blue wire if no hood pin switch is installed)

2.Turn Key to the ON position

3.Press program / valet button 5 times, after a few seconds the unit will flash the lights 5 times.

4.Push the valet/program button [again] the number of times that corresponds to the option number desired (1 thru 30). You must get a light flash after each button press. See chart on next page for option list.

5.When you reach the desired programming level, Press button #1, #2 #3 or #4 to change the option.

6.Turn Ignition OFF, Close hood and check for changed features. Change each option individually repeating #1-5.

18

Image 18
Contents Introduction DisclaimerTable of Contents PR PRE-INSTALLATION ConsiderationsComponent Mounting Green Mode B Optional Turbo Timer Input Wiring 9-PIN ConnectorGreen Mode a Start Activation Input Brown + Siren OutputMobile Accessory Protection Orange Negative Starter Disable/Anti-Grind OutputWiring 6-PIN High Current Connector IGN Wiring 3-PIN Connector Wiring 5-PIN ConnectorWhite +12V Brake Reset Carjack TriggerWiring 4-PIN Shock Sensor 22 Gauge wires Sensor AdjustmentBLUE/ORANGE Starter VIOLET/WHITE AUX Wire 4 PIN Output ConnectorBLUE/ORANGE Starter #3 GREEN/WHITE AUXPower Door Locks Wiring & System Types RED +12V Coil Power for external relaysDoor Lock Wiring Separate DRIVER’S Door Unlock Wiring Negative Trigger Door LocksTachless Mode Tachless AdjustmentImportant Notes Tach Finder Tach Mode & Tach Finder FeatureTach Finder Feature Tach ProgrammingTimed Crank Mode HOW to USE this FeatureDiesel Glow Plug Delay Programmable OptionsTo Engage Option Programming Option Programming Table Engine Monitoring Second +1 SecondProgrammable Option Descriptions AUTOLOCK/UNLOCK W/IGNITIONParking Lights on with Disarm Programmable OptionsPassive Locks Siren Chirps with Remote Start ActivationLock DURING/AFTER Remote Start Door LOCK/UNLOCK Pulse TimeDouble Unlock Pulse No Option / not UsedDiesel Glow Plug Delay ULTRA-SMART Tachless Voltage AdjustmentFactory Horn Chirps / Pulses Option Reset Restore to Default Programmable Option ResetAux #4 Time control 1 sec. to 255 sec. Default = 12 seconds Programming Transceivers & TransmittersRemote Programming Diagram Vehicle Operation Vehicle #2 ControlAlarm Trigger Diagnostics Remote Start TroubleshootingRemote Start Troubleshooting Engine Cranks Vehicle but Vehicle Never StartsNo Response TO/FROM Remote Jumper PIN Diagram Securing JumpersAntenna Diagram CS-2011DPJumper IGN #2 Data Port Diagram OFA