•Adjustment Method of REG3_LOW1 (item number: 747)
Set LCD display
REG3L1 **
747
**: Adjusted value
1.Connect a digital voltmeter to the TP1907 (REGO3) on the MAIN board, and adjust [SPEED CONTROL +] key (voltage up) or [SPEED CONTROL
digital voltmeter
MAIN board
TP1907 (REGO3)
TP1616 (GND)
MZ-B10
•Adjustment Method of REG3_HIGH (item number: 749)
Set LCD display
REG3 H **
749
**: Adjusted value
1.Connect a digital voltmeter to the TP1907 (REGO3) on the MAIN board, and adjust [SPEED CONTROL +] key (voltage up) or [SPEED CONTROL
digital voltmeter
MAIN board
TP1907 (REGO3)
TP1616 (GND)
2.Press the X key on the set or the key on the remote commander to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 25)
•Adjustment Method of REG3_LOW2 (item number: 748)
Set LCD display
REG3L2 **
748
**: Adjusted value
1.Connect a digital voltmeter to the TP1907 (REGO3) on the MAIN board, and adjust [SPEED CONTROL +] key (voltage up) or [SPEED CONTROL
digital voltmeter
MAIN board
TP1907 (REGO3)
TP1616 (GND)
2.Press the X key on the set or the key on the remote commander to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 25)
•Adjustment Method of VREC_LOW (X2 speed) (item number: 751)
Set LCD display
VREC L **
751
**: Adjusted value
1.Connect a digital voltmeter to the TP1620 (VREC) on the MAIN board, and adjust [SPEED CONTROL +] key (voltage up) or [SPEED CONTROL
digital voltmeter
MAIN board
TP1620 (VREC)
TP1616 (GND)
2. Press the X key on the set or the |
|
|
| key on the remote | 2. Press the X key on the set or the |
|
|
| key on the remote |
|
|
| |||||||
commander to write the adjusted value. | commander to write the adjusted value. | ||||||||
Adjustment and Connection Location: MAIN board | Adjustment and Connection Location: MAIN board | ||||||||
| (see page 25) |
| (see page 25) |
23