5Rewriting of the adjustment value.
1.After CD overall adjustment, switch to manual mode No. 321 in the condition the disc is in.
2.Press – key on the remote control unit to set 1 step down the adjustment value of No. 321, and press the pause key on the remote control unit to write this value to NV.
3.Press the >B key on the remote control unit to switch to manual mode No. 323.
4.Press the pause key on the remote control unit to set to the automatic adjustment.
During adjusting automatically, the adjustment value turns on and off, so wait for the time the adjustment value is on.
5.Press the >B key on the remote control unit to switch to manual mode No. 345.
6.Note down the current adjustment value of No. 345 (value X). Use the + and – keys on the remote control unit to set the adjustment value of No. 345 to the value (Y) determined by the formula below, and press the pause key on the remote control unit to write this value to NV.
Formula: X x 1.18 = Y
*Since X and Y are 2’sC, attention must be paid to codes. And the maximum value of Y must be 7Fh. (Never set it to the negative value.)
Example: Since X = 2Bh, Y = 2Bh x 1.18 = 33h
6Change the disc to MO overall adjustment disc (GA1 disc). Switch to manual mode No.114.
Press the pause key on the remotecontrol unit to set to the automatic adjustment.
After adjustment, pull out the battery from the set to turn off the power.
Then insert the battery again.
7MO overall adjustment.
Microprocessor Version 1.20 and higher
1Clear NV.
2Electric offset adjustment.
3CD overall adjustment.
4Rewriting of the adjustment value.
1.After CD overall adjustment, switch to manual mode No. 321 in the condition the disc is in.
2.Press – key on the remote control unit to set 1 step down the adjustment value of No. 321, and press the pause key on the remote control unit to write this value to NV.
3.Press the >B key on the remote control unit to switch to manual mode No. 323.
4.Press the pause key on the remote control unit to set to the automatic adjustment.
During adjusting automatically, the adjustment value turns on and off, so wait for the time the adjustment value is on.
5.Press the >B key on the remote control unit to switch to manual mode No. 345.
6.Note down the current adjustment value of No. 345 (value X). Use the + and – keys on the remote control unit to set the adjustment value of No. 345 to the value (Y) determined by the formula below, and press the pause key on the remote control unit to write this value to NV.
Formula: X x 1.18 = Y
*Since X and Y are 2’sC, attention must be paid to codes. And the maximum value of Y must be 7Fh. (Never set it to the negative value.)
Example: Since X = 2Bh, Y = 2Bh x 1.18 = 33h
5Change the disc to MO overall adjustment disc (GA1 disc). Switch to manual mode No.114.
Press the pause key on the remotecontrol unit to set to the automatic adjustment.
After adjustment, pull out the battery from the set to turn off the power.
Then insert the battery again.
6MO overall adjustment.
4-7-2. Overall CD and MO adjustment method
1.Set the TEST MODE and press VOL – key or . key to set the Overall Adjustment mode.
Main unit LCD display
ASS
2.Insert CD disc in the set, and press . key to set the Overall CD Adjustment mode.
Automatic adjustments are made.
Main unit LCD display
XXX:
XXX:Item No. for which an adjustment is being executed.
YY:Adjustment Value
3.If NG in the overall CD adjustments, return to Reset NV and perform from the electrical offset adjustment again.
The NG item and “ng” alternately flash on the main unit LCD display.
XXX:
n
XXX:NG item No.
YY:Adjustment Value
4.If OK through the overall CD adjustments, then perform overall MO adjustments.
Main unit LCD display
End:cd
5.Insert MO disc in the set, and press > N key to set the Overall MO Adjustment mode. Automatic adjustments are made.
Main unit LCD display
XXX:
XXX:Item No. for which an adjustment is being executed.
YY:Adjustment Value
10