MZ-E300
3.Each test item is assigned with a
4-5. OVERALL ADJUSTMENT MODE
4-5-1. Outline of the function
Change Major
Item
|
|
|
|
|
|
|
| key |
| x key | |
|
|
| |||
> N |
| ||||
|
|
|
|
| |
|
|
|
|
|
|
|
| Change Middle |
| ||
|
| Item |
|
|
|
|
| key |
| x key | |
|
|
| |||
> N | |||||
|
|
|
|
| |
|
|
|
|
|
|
|
| Change Minor |
| ||
|
| Item |
|
|
|
|
|
|
|
|
|
+key : 100th place of mode number increase
key : 100th place of mode number decrease
+key : 10th place of mode number increase
key : 10th place of mode number decrease
>N key : Unit place of mode number increase
.key : Unit place of mode number decrease
This mode is designed to adjust the servo system automatically by going through all the adjustment items.
Usually, this mode is used to perform automatic adjustments when servicing the set.
4-6. NV RESET
Power: Connect the battery terminals to a stable DC 1.5V power supply, or insert fresh batteries (size “AA”, IEC “LR6”).
Two different methods apply for NV reset, depending on whether the main unit or a remote control unit is used.
NV reset via main unit
1. | Enter test mode. | ||||
|
|
|
|
|
|
2. | Use the | – | key or the | . | key to set the device to Overall |
Change Adjustment | + key : Up |
Value | key : Down |
Write Adjustment
Value
Xkey : When adjusted value is changed : Adjusted value is written.
When adjusted value is not changed : That item is adjusted automatically.
4.During each test mode, the display is changed from one to another each time DISPLAY key is pressed (Remote control only).
Address Value & Adjustment Value
LCD display
011XXXSXX
Block Error Value & Adjustment Value
LCD display
011 XX BXX
ADIP Error Value & Adjustment Value
LCD display
011 XX AXX
* Functions are displayed, Jitter Value & Adjustment Value but cannot be used via
Adjustment mode. |
ASS
3. Press the PLAY MODE/DISPLAY key. “CL” starts to flash.
AdJcL
4.Press the PLAY MODE/DISPLAY key once more. “CL” stops flashing and remains lit, thus concluding NV reset.
AdJ cL
5. Press the x key to return to test mode.
NV reset via remote control
1.Set the TEST MODE.
2.Set the Manual mode and set the item No. 021, Reset NV. LCD display
021 AAAS CC
LCD display
this unit.
011XXXJXX
Power Adjustment Value
LCD display
731 XX VXX
After the voltage indicator appears, press the DISPLAY key twice.
Memory Monitor Mode
XXX: Each Value
XX: Adjustment Value
for Item number
Note: In the Power mode, the item title display is only displayed.
5.To terminate the Manual mode and return to the TEST MODE, press x key.
3.Press X key on the remote control. LCD display
021AAAS CC
Flash CC
4.Press X key on the remote control again. LCD display
021 AAAS CC
5.Press x key to terminate the Manual mode and return to the
TEST MODE.
8