HUAWEI MG323 GSM M2M Module |
|
|
| ||
Hardware Guide |
|
| Description of the Application Interfaces | ||
Table | |||||
|
|
|
|
|
|
| Pin No. | Signal Name | I/O | Description |
|
|
|
|
|
|
|
| 20 | TERM_ON | I | Pin for controlling |
|
|
|
|
|
|
|
| 22 | RESET | I | Pin for resetting the hardware |
|
|
|
|
|
|
|
3.4.2Power-On Time Sequence
Make sure that the MG323 module is powered on at the voltage and operating temperature in the recommended range. Otherwise, the module may get damaged or work improperly.
External application interfaces must be powered on after the module is powered on.
You can power on the MG323 module through the TERM_ON interface. The software will report relevant information according to the actual settings after the module is powered on. For example, the AT command automatically reports ^SYSSTART[1]. In this case, the external VIO interface is enabled and supplies 2.8 V power.
[1]For specific setting information about the
Figure 3-4 shows the power-on time sequence.
Figure |
|
|
|
| |
VBAT | 250 ms (min) |
|
|
|
|
|
|
|
|
| |
|
|
| 1s |
| |
TERM_ON |
|
|
|
| |
|
|
|
|
| |
|
| Sampling period used to |
|
|
|
| 6.6 ms | select Vgpio/Vmem |
|
|
|
VIO | 2.8 V |
|
|
| |
6.3 ms | 2.3 V |
|
|
| |
|
| Vio is set |
|
|
|
Fetch Ext |
| 130 ms | HW | Nominal | |
Code |
| ||||
|
| Init | SW Debouncing | SW | |
|
|
|
| 185 ms |
|
Issue 06 | Huawei Proprietary and Confidential | 19 | |