Huawei MG323 manual Function Signal Name Waveform Remarks Level, Power supply, Than 3.3

Page 37

HUAWEI MG323 GSM M2M Module

 

 

 

 

Hardware Guide

 

 

Electrical and Reliability Features

 

 

 

 

 

 

 

 

Pin No.

Signal Name

Pin No.

 

Signal Name

 

 

 

 

 

 

 

 

 

11

GND

12

 

INTMIC_P

 

 

 

 

 

 

 

 

 

13

NC

14

 

EXTMIC_P

 

 

 

 

 

 

 

 

 

15

NC

16

 

EXTMIC_N

 

 

 

 

 

 

 

 

 

17

NC

18

 

GND

 

 

 

 

 

 

 

 

 

19

NC

20

 

TERM_ON

 

 

 

 

 

 

 

 

 

21

NC

22

 

RESET

 

 

 

 

 

 

 

 

 

23

NC

24

 

UART1_DCD

 

 

 

 

 

 

 

 

 

25

LED_STATUS

26

 

NC

 

 

 

 

 

 

 

 

 

27

NC

28

 

UART1_CTS

 

 

 

 

 

 

 

 

 

29

UART1_RD

30

 

NC

 

 

 

 

 

 

 

 

 

31

NC

32

 

UART1_DTR

 

 

 

 

 

 

 

 

 

33

UART1_TD

34

 

UART1_RTS

 

 

 

 

 

 

 

 

 

35

VCOIN

36

 

UART1_DSR

 

 

 

 

 

 

 

 

 

37

NC

38

 

UART1_RING

 

 

 

 

 

 

 

 

 

39

NC

40

 

VIO

 

 

 

 

 

 

 

 

 

41

GND

42

 

VBAT

 

 

 

 

 

 

 

 

 

43

GND

44

 

VBAT

 

 

 

 

 

 

 

 

 

45

GND

46

 

VBAT

 

 

 

 

 

 

 

 

 

47

GND

48

 

VBAT

 

 

 

 

 

 

 

 

 

49

GND

50

 

VBAT

 

 

 

 

 

 

 

 

Table 5-4lists electrical features (typical values) measured when no external device is connected to the MG323 module through the 50-pin B2B interface.

Table 5-4Electrical features of application interfaces

 

Function

Signal Name

I/O

 

Waveform and

Remarks

 

 

 

 

 

 

 

Level

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

VBAT

P

 

VI=3.30 V to 4.80

Pins 42, 44, 46, 48, and 50 are power supply

 

 

interface

 

 

 

V

pins used to supply the MG323 module with

 

 

 

 

 

 

VItypical=3.80 V

power. When the module transmits signals at

 

 

 

 

 

 

the maximum power, the transient current can

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reach about 2 A, which may result in VBAT

 

 

 

 

 

 

 

 

voltage great drop. The VBAT power voltage

 

 

 

 

 

 

 

for the MG323 module should not be lower

 

 

 

 

 

 

 

 

than 3.3 V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Issue 06 (2013-06-13)

 

Huawei Proprietary and Confidential

37

 

 

Copyright © Huawei Technologies Co., Ltd.

 

 

 

 

 

 

Image 37
Contents Hardware Guide Issue DateNo Warranty History About This DocumentVersion Date Chapter Descriptions CreationVersion Date Chapter Descriptions Updated -3 Recommended Updated .8 Audio InterfaceSpecifications of the antenna interface Contents Electrical and Reliability Features Overview IntroductionOverall Description Feature DescriptionAbout This Chapter Function OverviewDRX=5 DRX=9 DRX=2SMS Gprs Gprs ClassCircuit Block Diagram Application Block Diagram2Circuit block diagram of the MG323 module Description of the Application Interfaces B2B Connector InterfaceMin Tpy Max Pin Pin Name Description DC Characteristics NormalTermon ResetUART1DCD LedstatusOverview Power InterfaceVIO VbatVbat Interface Pin No Signal Name DescriptionGND Vcoin DCEVcoin Interface Power-On and Power-Off Time SequenceVIO Interface Pin for controlling power-on and power-off Power-On Time SequencePin for resetting the hardware Power-Off Time Sequence Signal Control InterfaceReset Pin for network status LED Input Signal Control PinsApplication Device Output Signal Control PinWorking or Network Status Uart Interface Pin No Signal Name Description Feature DirectionDCE receive DTE transmits DTE to DCE Data Serial data Circuit Recommended for the Uart InterfaceDCE data DTE is ready DTE to DCE Terminal ready DCE data set DCE is ready DCE to DTE ReadyPower supply of the SIM card Clock signal of the SIM cardData signal of the SIM card Reset signal of the SIM cardCircuit Recommended for the SIM Card Interface Ground signal of the SIM cardAudio Interface 12External circuit for 32 Ω handsets/16 Ω headsets13External circuit for the microphone interface Antenna Interface Antenna InstallationEnvironmental Type Material Condition Coaxial Cable and RF ConnectorHuawei MG323 GSM M2M Module Hardware Guide Antenna Interface Specification Minimum Typical Maximum Unit Value RF Specifications of the Antenna InterfaceESD Protection for the Antenna Interface Uplink frequency range GSM 824 849 MHzSpecification Minimum Typical Maximum Unit Value Polarization Linear polarization Pattern Omnidirectional Specifications of the Antenna InterfaceSymbol Specification Minimum Value Maximum Value Unit Electrical and Reliability FeaturesExternal power voltage Extreme Working ConditionsSpecification Minimum Value Maximum Value Unit Operating and Storage Temperatures and HumidityPin No Signal Name Electrical Criteria of Application InterfacesPower supply Function Signal Name Waveform Remarks LevelVoltage great drop. The Vbat power voltage Than 3.3Power pin Pins 41, 43, 45, 47, and 49 are power GND ExternalVBAT=0 LedstatuUART1RIN UART1 UART1RDUART1DSR UART1RTS UART1DTR UART1CTS UART1DCD Input Power Supply Power Supply FeaturesWorking Current Parameter Minimum Value Typical Value Maximum Value UnitConfiguration Working Mode Typical value Unit RemarkBand Typical Unit Configuration Value Reliability FeaturesUp/1 Down 123 Test Condition StandardTest Condition Standard ESD Test Standard Contact Discharge Air Discharge ESD FeaturesEN61000-4-2 ±4 kV ±8 kV Dimensions Mechanical SpecificationsDimensions L x W x H 35 mm x 32.5 mm x 3.05 mm 1Dimensions of the MG323 module unit mm Dimensions of the B2B ConnectorModel Stacking HRS Number Height mm 5Structure fixing hole MG323 Module Installation Description6MG323 module installation 7Machine screw dimensions Specification Selection for Fasteners8Nut dimensions 1Circuits of typical interfaces in the MG323 module Appendix a Circuits of Typical InterfacesAcronym or Abbreviation Expansion Appendix B Acronyms and AbbreviationsPCB PbcchPDU RTC
Related manuals
Manual 239 pages 48.54 Kb