HUAWEI MG323 GSM M2M Module |
|
| ||
Hardware Guide | Electrical and Reliability Features | |||
|
|
|
|
|
| Item | Test Condition | Standard |
|
|
|
|
|
|
| Drop test | First case: 0.3 m in height. Drop the | IEC60068 |
|
|
| MG323 module on the marble |
|
|
|
| terrace with one surface facing |
|
|
|
| downwards twice. Six surfaces |
|
|
|
| should be tested. |
|
|
|
| Second case: 0.8 m in height. Drop |
|
|
|
| the MG323 module on the marble |
|
|
|
| terrace with one surface facing |
|
|
|
| downwards twice. Six surfaces |
|
|
|
| should be tested. |
|
|
|
|
|
|
|
5.7 ESD Features
Pay great attention to ESD protection when using the MG323 module. To ensure that the working reference GND is connected to the MG323 module and user interface board properly, you are recommended not to spray a coated insulation on the structure fixing hole (connecting with the main reference GND of the user interface board) and connect the hole with the MG323 module through the metal fastener or other
Table
Table
ESD Test Standard | Contact Discharge | Air Discharge |
|
|
|
| ±4 kV | ±8 kV |
|
|
|
Issue 06 | Huawei Proprietary and Confidential | 44 | |
Copyright © Huawei Technologies Co., Ltd. | |||
|
|