Huawei MG323 manual ESD Features, ESD Test Standard Contact Discharge Air Discharge

Page 44

HUAWEI MG323 GSM M2M Module

 

 

Hardware Guide

Electrical and Reliability Features

 

 

 

 

 

 

Item

Test Condition

Standard

 

 

 

 

 

 

 

Drop test

First case: 0.3 m in height. Drop the

IEC60068

 

 

 

MG323 module on the marble

 

 

 

 

terrace with one surface facing

 

 

 

 

downwards twice. Six surfaces

 

 

 

 

should be tested.

 

 

 

 

Second case: 0.8 m in height. Drop

 

 

 

 

the MG323 module on the marble

 

 

 

 

terrace with one surface facing

 

 

 

 

downwards twice. Six surfaces

 

 

 

 

should be tested.

 

 

 

 

 

 

 

5.7 ESD Features

Pay great attention to ESD protection when using the MG323 module. To ensure that the working reference GND is connected to the MG323 module and user interface board properly, you are recommended not to spray a coated insulation on the structure fixing hole (connecting with the main reference GND of the user interface board) and connect the hole with the MG323 module through the metal fastener or other low-resistance fastener. For specific installation method and fastener specification, see “6.4 MG323 Module Installation Description."

Table 5-9lists the test results of the ESD performance of the MG323 module according to the EN61000-4-2 standard.

Table 5-9ESD performance

ESD Test Standard

Contact Discharge

Air Discharge

 

 

 

EN61000-4-2

±4 kV

±8 kV

 

 

 

Issue 06 (2013-06-13)

Huawei Proprietary and Confidential

44

Copyright © Huawei Technologies Co., Ltd.

 

 

Image 44
Contents Issue Date Hardware GuideNo Warranty About This Document HistoryVersion Date Chapter Descriptions CreationVersion Date Chapter Descriptions Specifications of the antenna interface Updated .8 Audio InterfaceUpdated -3 Recommended Contents Electrical and Reliability Features Introduction OverviewFeature Description Overall DescriptionAbout This Chapter Function OverviewDRX=2 DRX=5 DRX=9SMS Gprs Gprs ClassApplication Block Diagram Circuit Block Diagram2Circuit block diagram of the MG323 module B2B Connector Interface Description of the Application InterfacesPin Pin Name Description DC Characteristics Normal Min Tpy MaxReset TermonUART1DCD LedstatusPower Interface OverviewVIO VbatPin No Signal Name Description Vbat InterfaceGND Vcoin DCEVIO Interface Power-On and Power-Off Time SequenceVcoin Interface Pin for resetting the hardware Power-On Time SequencePin for controlling power-on and power-off Reset Signal Control InterfacePower-Off Time Sequence Input Signal Control Pins Pin for network status LEDWorking or Network Status Output Signal Control PinApplication Device Pin No Signal Name Description Feature Direction Uart InterfaceCircuit Recommended for the Uart Interface DCE receive DTE transmits DTE to DCE Data Serial dataDCE data DTE is ready DTE to DCE Terminal ready DCE data set DCE is ready DCE to DTE ReadyClock signal of the SIM card Power supply of the SIM cardData signal of the SIM card Reset signal of the SIM cardGround signal of the SIM card Circuit Recommended for the SIM Card Interface12External circuit for 32 Ω handsets/16 Ω headsets Audio Interface13External circuit for the microphone interface Antenna Installation Antenna InterfaceCoaxial Cable and RF Connector Environmental Type Material ConditionHuawei MG323 GSM M2M Module Hardware Guide Antenna Interface RF Specifications of the Antenna Interface Specification Minimum Typical Maximum Unit ValueESD Protection for the Antenna Interface Uplink frequency range GSM 824 849 MHzSpecification Minimum Typical Maximum Unit Value Specifications of the Antenna Interface Polarization Linear polarization Pattern OmnidirectionalElectrical and Reliability Features Symbol Specification Minimum Value Maximum Value UnitExternal power voltage Extreme Working ConditionsOperating and Storage Temperatures and Humidity Specification Minimum Value Maximum Value UnitPin No Signal Name Electrical Criteria of Application InterfacesFunction Signal Name Waveform Remarks Level Power supplyVoltage great drop. The Vbat power voltage Than 3.3Pins 41, 43, 45, 47, and 49 are power GND External Power pinVBAT=0 LedstatuUART1DSR UART1RTS UART1DTR UART1CTS UART1DCD UART1 UART1RDUART1RIN Power Supply Features Input Power SupplyWorking Current Parameter Minimum Value Typical Value Maximum Value UnitBand Typical Unit Working Mode Typical value Unit RemarkConfiguration Reliability Features Configuration ValueUp/1 Down 123 Test Condition StandardTest Condition Standard EN61000-4-2 ±4 kV ±8 kV ESD FeaturesESD Test Standard Contact Discharge Air Discharge Dimensions L x W x H 35 mm x 32.5 mm x 3.05 mm Mechanical SpecificationsDimensions Dimensions of the B2B Connector 1Dimensions of the MG323 module unit mmModel Stacking HRS Number Height mm MG323 Module Installation Description 5Structure fixing hole6MG323 module installation Specification Selection for Fasteners 7Machine screw dimensions8Nut dimensions Appendix a Circuits of Typical Interfaces 1Circuits of typical interfaces in the MG323 moduleAppendix B Acronyms and Abbreviations Acronym or Abbreviation ExpansionPbcch PCBPDU RTC