OPERATION | ||
|
|
|
SETUP MENU FEATURES
The Setup Menu gives access to the Setup Configuration. Stored in the setup configuration are user parameters that generally only need to be set at installation. The parameters are grouped as shown in the following table.
PARAMETER | DEFINITION |
P.1 through P.99 | Unsecured Parameters (always adjustable) |
P.101 through P.199 | Diagnostic Parameters (always read only) |
P.501 through P.599 | Secured Parameters (only accessible through a p.c. or palm application) |
|
|
SET-UP FEATURES MENU
(See Figure B.17b and B.17c for specific Codes)
1.To access the
Change the value of the blinking parameter by rotat- ing the SET knob.
2.After changing a parameter it is necessary to press the Right hand button to save the new setting. Pressing the Left button will cancel the change.
3.To exit the
FIGURE B.17b - SETUP MENU
(Only parameters below can be accessed in Code 11313)
P.0 | P.7 | P.100 thru P.107 |
P.1 | P.8 |
|
P.2 | P.11 |
|
P.3 | P.12 |
|
P.4 | P.13 |
|
P.5 | P.80 |
|
P.6 | P.99 |
|
Mode Select
Panel (MSP4)
LED
Indicator
Left | Right | |
buttom | ||
button | ||
| ||
| SET Knob |
FIGURE B.17c - SETUP MENU
(All parameters can be accessed in Code 11456 and higher)
Mode Select
Panel (MSP4)
LED
Indicator
Left | Right | |
buttom | ||
button | ||
| ||