Lincoln Electric IM892-C Parameter Definition 503 Memory Button Disable, Mode Select Panel Lock

Models: IM892-C

1 83
Download 83 pages 9.61 Kb
Page 47
Image 47

B-31

 

OPERATION

B-31

 

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

 

 

 

 

 

P.503

Memory Button Disable

 

 

 

 

 

 

Disables the specified memory button(s). When a memory is disabled, welding procedures can-

 

 

 

 

 

not be restored from or saved to that memory. If an attempt is made to save or restore a dis-

 

 

 

 

 

abled memory, a message will be displayed on the Mode Select Panel indicating the memory

 

 

 

 

 

number is disabled. In multi-head systems, this parameter disables the same memory buttons

 

 

 

 

 

on both feed heads. This parameter can only be accessed using Weld Manager or Power

 

 

 

 

 

Wave Manager software.

 

 

 

 

 

 

 

 

 

 

P.504

Mode Select Panel Lock

 

 

 

 

 

 

Selects between several Mode Select Panel lockout preferences. When a Mode Select Panel

 

 

 

 

 

selection is locked and an attempt is made to change that parameter, a message will be dis-

 

 

 

 

 

played on the Mode Select Panel indicating the parameter is locked.

 

 

 

 

 

 

• All MSP Options Unlocked = All adjustable parameters on the Mode Select Panel are

 

 

 

 

 

unlocked.

 

 

 

 

 

 

• All MSP Options Locked = All knobs and buttons on the Mode Select Panel are locked.

 

 

 

 

 

 

• Start & End Options Locked = The Start and End parameters on the Mode Select Panel are

 

 

 

 

 

locked, all others are unlocked.

 

 

 

 

 

 

• Weld Mode Option Locked = The weld mode cannot be changed from the Mode Select Panel,

 

 

 

 

 

all others Mode Select Panel settings are unlocked.

 

 

 

 

 

 

• Wave Control Options Locked = The Wave Control parameters on the Mode Select Panel are

 

 

 

 

 

locked, all others are unlocked.

 

 

 

 

 

 

• Start, End, Wave Options Locked = The Start, End and Wave Control parameters on the

 

 

 

 

 

Mode Select Panel are locked, all others are unlocked.

 

 

 

 

 

 

• Start, End, Mode Options Locked = The Start, End and Weld Mode Select parameters on the

 

 

 

 

 

Mode Select Panel are locked, all others are unlocked.

 

 

 

 

 

 

This parameter can only be accessed using Power Wave Manager.

 

 

 

 

 

 

 

 

 

 

P.505

Setup Menu Lock

 

 

 

 

 

 

Determines if the setup parameters can be modified by the operator without entering a pass-

 

 

 

 

 

code.

 

 

 

 

 

 

• No = The operator can change any set menu parameter without first entering the passcode

 

 

 

 

 

even if the passcode is non-zero (default).

 

 

 

 

 

 

• Yes = The operator must enter the passcode (if the passcode is non-zero) in order to change

 

 

 

 

 

any setup menu parameters.

 

 

 

 

 

 

This parameter can only be accessed using Power Wave Manager.

 

 

 

 

 

 

 

 

 

 

P.506

Set User Interface Passcode

 

 

 

 

 

 

Prevents unauthorized changes to the equipment. The default passcode is zero which allows

 

 

 

 

 

full access. A nonzero passcode will prevent unauthorized:

 

 

 

 

 

 

• changes to memory limits

 

 

 

 

 

 

• saving to memory (if P.502 = Yes)

 

 

 

 

 

 

• changes to setup parameters (if P.505 = Yes)

 

 

 

 

 

 

This parameter can only be accessed using Power Wave Manager.

 

 

 

 

 

 

 

 

 

POWER FEED™ 25M

Page 47
Image 47
Lincoln Electric IM892-C manual Parameter Definition 503 Memory Button Disable, Mode Select Panel Lock, Setup Menu Lock