Lincoln Electric IM892-C manual 220

Models: IM892-C

1 83
Download 83 pages 9.61 Kb
Page 31
Image 31

B-15

OPERATION

B-15

 

 

 

STEEL AND STAINLESS SYNERGIC GMAW-P (PULSED MIG) WELDING

220

1.06

WFS AMPS

VOLTS TRIM

Less

More

Shorter

Longer

Deposition

Deposition

Arc

Arc

MSP4 OPERATION

WELD MODE

ELECTRODE AND GAS

 

 

WIRE SIZE

 

0.030

0.035

0.045

0.052

Steel(Crisp)

 

Ar(Mix)

 

95

12

22

201

Steel(Soft)

Ar(Mix)

 

---

14

19

28

Stainless

Ar/ CO2

 

66

36

46

---

Stainless

Ar/ CO2

 

62

32

42

---

Stainless

Ar/He/CO2

 

---

34

44

---

 

WAVEFORM CONTROL TECHNOLOGY

 

 

 

12

STEEL

 

 

IR PORT

.035"

 

 

 

 

 

SETUP

 

Pulse Crisp ArMix

 

 

WELD MODE

 

 

 

 

START OPTIONS

ARC CONTROL

 

 

 

 

END OPTIONS

 

 

SET

 

 

 

 

START OPTIONS

PREFLOW TIME

 

DESCRIPTION

 

 

0 - 25.0 seconds

Adjusts the time that shielding

 

gas flows after the trigger is

 

pulled

and prior to feeding wire.

RUN-IN WFS:

Run-in

sets the wire feed

Off, 30 to150 in/min.

 

speed from the time the trigger

 

is pulled until an arc is estab-

 

lished.

 

Start Procedure

The Start Procedure control s

 

the WFS, Trim a t a specified

 

time at t he beginning of t he

 

weld. During the start time, the

 

machine will ramp up or down

 

from the Start Procedure to the

 

preset Welding Procedure.

 

ARC CONTROL

ARC

 

DESCRIPTION

FOCUS

 

 

-10.0 (SOFT to

 

Arc Focus adjusts the arc from

10.0 (STIFF)

 

a wide, soft arc good for out of

 

 

position work to a narrow, stiff

 

 

arc preferred for faster travel

 

 

speeds. The pulse frequency is

 

 

lower with a soft arc and higher

 

 

with a stiff arc.

 

 

 

 

 

 

END OPTIONS

 

 

 

 

EFFECT / RANGE

 

 

FUNCTION

 

 

 

 

 

Spot Timer

Adjust the time welding will

 

0 to 120.0 Seconds

continue even if the trigger

 

 

is still pulled. This option

 

 

 

has no effect in 4-Step

 

 

 

Trigger Mode.

 

 

 

 

Postflow Time:

Adjusts the time that shielding

0 to 25.0 seconds

gas flows after the welding out-

 

put turns off.

 

 

 

 

Burnback: 0 to .25

The

burnback

time

is t he

Seconds

amount of time that the weld

 

output continues after the wire

 

stops feeding. It prevents the

 

wire from sticking in the puddle

 

and

prepares the end

of the

 

wire for the next arc start.

 

Crater Procedure

Crater P rocedure

controls

the

 

WFS and Trim for a

specified

 

time

at

the end

of t he wel d

 

after

the trigger

is

released.

 

During

the Crater

time,

t he

 

machine will ramp up or down

 

from

the Weld Procedure

to

 

the Crater Procedure.

 

 

POWER FEED™ 25M

Page 31
Image 31
Lincoln Electric IM892-C manual 220