B-36

OPERATION

B-36

 

 

 

DUAL PROCEDURE/MEMORY OPERATION

(For Code 11456 and Higher)

The Dual Procedure/Memory buttons performs three functions:

Weld procedure selection

Memory save and recall

Limits setting

There are two procedure memories (A and B) and eight user memories (1-8).

Procedure Memory vs. User Memory

Procedure memory is used while welding. Changes to the weld procedure (WFS, voltage, arc control, etc.) immediately change the contents inside the selected procedure memory.

 

USER MEMO-

 

 

RIES ARE COPIED

 

PROCEDURE

TO PROCEDURE

USER

MEMORIES

MEMORY

MEMORIES

 

A GUN B

1 2 3 4

5 6 7 8

User memories work by copying the weld procedure from one of the eight memories into either the A or B procedure. Weld procedures are saved into the memo- ries only when the operator chooses.

Using Procedure Memories

Procedure memories can be selected by choosing either "A" or "B" procedure directly with the memory panel, or by selecting "GUN" and using a dual proce- dure gun to select between procedure "A" and "B". When selecting procedures with the gun switch, "A" or "B" will flash to show which procedure is active.

PRESS TO

SELECT

PROCEDURE

A GUN B

1 2 3 4

5 6 7 8

USER MEMORIES

Recall a memory with memory buttons

To recall a user a memory, press one of the six user memory buttons. The memory is recalled when the button is released. Do not hold the button for more than two seconds when recalling a user memory.

Recall a memory with the gun trigger

If desired, memories 2 through 8 can be recalled with the gun trigger. For example, to recall memory 3, quick- ly pull and release the gun trigger 3 times without weld- ing.

Note: the wire feeder is factory set with this feature dis- abled. Use the SETUP menu and change P.4 to enable memory recall with the gun trigger.

Save a memory with memory buttons

To save a memory, press and hold the desired memo- ry button for two seconds. When the button is initially pressed, the corresponding LED will illuminate. After two seconds, the LED will turn off. Do not hold the button for more than 5 seconds when saving a user memory.

Note: that memories may be locked in the set-up menu to prevent accidental overwrite of the memories. If an attempt is made to save a memory when memory sav- ing is locked, the message "Memory save is Disabled!" will appear briefly in the MSP4 display.

RECALL

SAVE

 

 

PRESS 1

PRESS 2

 

 

SECOND

SECONDS

 

 

A GUN B

 

 

 

1

2

3

4

5 6 7 8