Lincoln Electric IM892-C manual Preflow, Run-In, Weld

Models: IM892-C

1 83
Download 83 pages 9.61 Kb
Page 59
Image 59

B-43

OPERATION

B-43

 

 

 

EXAMPLE 1 - 2 STEP TRIGGER: Simple operation The simplest trigger operation occurs with a 2 Step trigger and the Start, Crater and Burnback functions all set to OFF. (See Figure B.19)

For this sequence,

PREFLOW:

Shielding gas begins to flow immediately when the gun trigger is pulled.

RUN-IN:

After preflow time expires, the power source regulates to the welding output and wire is advanced towards the work piece at the Run-In WFS. If an arc is not established within 1.5 seconds, the wire feed speed will jump to the welding wire feed speed

WELD:

The power source output and the wire feed speed continue at the weld settings for as long as the trigger is pulled.

POSTFLOW: As soon as the trigger is released, the power source output and the wire feed speed are turned OFF. Shielding gas continues until the post flow timer expires.

FIGURE B.19

Trigger Pulled

Arc Established

2 Step Trigger

Start = OFF

Crater = OFF

Burnback = OFF

Trigger Released

Idle

Preflow

Run-In

Weld

Postflow

Idle

 

 

 

 

 

 

Shielding O n

Gas

O ff

 

Weld

Power

 

Source

1.5 sec max.

Output

 

 

O ff

Weld

WFS

Run- in

O ff

POWER FEED™ 25M

Page 59
Image 59
Lincoln Electric IM892-C manual Preflow, Run-In, Weld