If the passcode does not equal zero (0000), enter the passcode now. If the passcode has been forgotten, a p.c. computer application or Palm O.S. application is required to change the passcode

Memory Value

Low Limit

 

High Limit

200

 

 

 

HI = 200

LO = 180

 

WELD WFS

WELD MODE

 

START OPTIONS

ARC CONTROL

 

END OPTIONS

Parameter Name

If the passcode has been set to zero (0000), SETUP will illuminate on the MSP4 panel and the display will show the following:

Four items show on the MSP4 panel.

Memory Value

High Limit

Low Limit

Parameter Name

One of these items will flash to indicate which item will change when the MSP4 encoder is rotated. Press the right button on the MSP4 panel to select the item to change.

200

HI = 200

LO = 180

WELD WFS

WELD MODE

START OPTIONS

ARC CONTROL

END OPTIONS

The memory value must always be less than or equal to the high limit, and greater than or equal to the low limit.

After setting limits, press the memory button with the flashing LED. The MSP4 will ask to save or discard the limit changes just made. Press the left MSP4 for button (YES) to save and enable the limits and exit. Press the right MSP4 button (NO) to exit and leave limits unchanged.

Enabling/Disabling Limits

Enable/Disable

Limits: Press

10 seconds

A GUN B

1 2 3 4

5 6 7 8

Limits for each memory may be enabled or disabled by pressing and hold the appropriate memory button for 10 seconds. Release the memory button when the MSP4 display shows the following:

MEMORY 2 LIMITS

ENABLE/DISABLE

WELD MODE

START OPTIONS

ARC CONTROL

END OPTIONS

If the passcode does not equal zero, enter the passcode now. If the passcode is zero (0000), SETUP will light

Rotate to

Press to

Change

select item

Value.

to change.

The Limits Setup menu shows a list of all parameters available for the weld mode stored in the memory chosen. For example, if limits are being set for a stick (SMAW) mode, parameters such as Run-in WFS and Postflow will not appear.

To lock a parameter to a specific value that can- not be changed, set the high and low limits to the same value.

ENABLE

LIMITS?

Yes

No

WELD MODE

START OPTIONS

ARC CONTROL

END OPTIONS

and the MSP4 displays the following:

Press the left MSP4 button (YES) to enable limits or the right MSP4 button (NO) to disable limits. Disabling limits does not change any limits values that may have been previously set.