OPERATION

B-29

 

 

 

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

 

 

 

 

 

 

 

 

P.16

Push-Pull Gun Knob Behavior

 

 

 

 

 

 

 

Determines how the potentiometer on the Push/Pull torch will behave.

 

 

 

 

 

 

 

• Gun Pot Enabled = The welding wire feed speed is always controlled by the potentiometer on

 

 

 

 

 

 

the push-pull gun (default). The left front panel knob is only used to adjust Start and Crater

 

 

 

 

 

 

wire feed speed.

 

 

 

 

 

 

 

• Gun Pot Disabled = The wire feed speed is always controlled by the left front panel knob. This

 

 

 

 

 

 

setting is useful when the operator wishes to have wire feed speed settings recalled from

 

 

 

 

 

 

memories and not have the potentiometer "overwrite" the setting.

 

 

 

 

 

 

 

• Gun Pot Procedure A = When in procedure A, the welding wire feed speed is controlled by the

 

 

 

 

 

 

potentiometer on the push-pull gun. When in procedure B, the welding wire feed speed is con-

 

 

 

 

 

 

trolled by the left front panel knob. This setting allows a fixed wire feed speed to be selected

 

 

 

 

 

 

in procedure B and not have the potentiometer "overwrite" the setting when procedure

 

 

 

 

 

 

changes.

 

 

 

 

 

 

 

 

 

 

 

 

P.80

Sense From Studs

 

 

 

 

 

 

 

Use this option for diagnostic purposes only. When power is cycled, this option is automatically

 

 

 

 

 

 

reset to False.

 

 

 

 

 

 

 

• False = Voltage sensing is determined by the DIP switch configuration and the selected weld

 

 

 

 

 

 

mode (default).

 

 

 

 

 

 

 

• True = Voltage sensing is forced to "studs" regardless of the DIP switch configuration and

 

 

 

 

 

 

selected weld mode.

 

 

 

 

 

 

 

 

 

 

 

 

P.99

Show Test Modes

 

 

 

 

 

 

 

Most power sources contain weld modes used for calibration and test purposes. By default, the

 

 

 

 

 

 

machine does not include test weld modes in the list of weld modes that are available to the

 

 

 

 

 

 

operator. To manually select a test weld mode, set this option to "Yes". When the power source

 

 

 

 

 

 

is turned off and back on again, the test modes will no longer appear in the mode list. Test weld

 

 

 

 

 

 

modes typically require the machine output to be connected to a grid load and cannot be used

 

 

 

 

 

 

for welding.

 

 

 

 

 

 

 

 

 

 

 

 

P.100

View Diagnostics

 

 

 

 

 

 

 

Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select

 

 

 

 

 

 

"Yes" to access the diagnostic options in the menu. Additional parameters will now appear in

 

 

 

 

 

 

the setup menu (P.101, P.102, etc).

 

 

 

 

 

 

 

 

 

 

 

 

P.101

View Event Logs

 

 

 

 

 

 

 

Used for viewing all the system event logs. Press the right MSP Button to enter the option.

 

 

 

 

 

 

Rotate Set knob to select the desired system log to read. Press the right button again to enter

 

 

 

 

 

 

the selected log. Rotating the Set knob will scroll through the event log, displaying the log index

 

 

 

 

 

 

number, event code and some other data. Press the left button to back out to select another

 

 

 

 

 

 

log. Press the left button again to exit this option.

 

 

 

 

 

 

 

 

 

 

 

 

P.102

View Fatal Logs

 

 

 

 

 

 

 

Used for viewing all the system fatal logs. Press the right MSP Button to enter the option.

 

 

 

 

 

 

Rotate Set knob to select the desired log to read. Press the right button again to enter that log.

 

 

 

 

 

 

Rotating the Set knob will scroll through the log, displaying the log index number and fatal

 

 

 

 

 

 

code. Press the left button to back out to select another log. Press the left button again to exit

 

 

 

 

 

 

this option.

 

 

 

 

 

 

 

 

 

 