APPENDIX A: EMC INFORMATION

Guidance and Manufacturer’s Declaration- Electromagnetic Emissions:

This device is intended for use in the electromagnetic environment specified below. The user of this device should make sure it is used in such an environment.

Emissions Test

 

Compliance

 

Electromagnetic Environment-Guidance

Harmonic emissions

 

Class A

IEC61000-3-2

 

 

 

Voltage fluctuations

/

 

Flicker emissions

 

Complies

IEC61000-3-3

 

 

The device is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network.

Guidance and Manufacturer’s Declaration- Electromagnetic Immunity:

This device is intended for use in the electromagnetic environment specified below. The user of this device should make sure it is used in such an environment.

 

 

 

 

 

 

 

 

Electromagnetic

 

 

Immunity Test

 

IEC60601 test level

 

 

Compliance

 

 

 

 

 

Environment-Guidance

 

 

 

 

 

 

 

 

 

 

Electrostatic

 

 

 

 

 

 

Floors should be wood, concrete or

 

±6kV contact

 

 

±6kV contact

 

ceramic tile. If floors are covered

Discharge(ESD)

 

 

 

 

 

±8kV air

 

 

±8kV air

 

with synthetic material, the relative

IEC61000-4-2

 

 

 

 

 

 

humidity should be at least 30 %.

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical fast

 

±2kV for power supply

±2kV for power supply

Mains power quality should be that

 

transient/ burst

 

line

 

 

line

 

of atypical commercial or hospital

 

IEC61000-4-4

 

±1kV for input/out line

 

 

±1kV for input/out line

 

environment

 

 

 

 

 

 

 

 

Surge

 

±1kV for differential

±1kV for differential

Mains power quality should be that

 

mode

 

 

mode

 

of atypical commercial or hospital

IEC61000-4-5

 

 

 

 

 

±2kV for common mode

±2kV for common mode

environment.

 

 

 

 

 

 

 

 

 

 

 

Voltage dips,

<5 % UT(>95 % dip in

<5 % UT(>95 % dip in

Mains power quality should be that

short

UT)for 0,5 cycle

 

 

UT) for 0,5 cycle

 

of atypical commercial or hospital

interruptions and

40 % UT(60 % dip

in

40 % UT(60 % dip

in

environment. If the user of this

voltage

UT)for 5 cycles

 

 

UT) for 5 cycles

 

device requires continued operation

variations on

70 % UT(30 % dip in

70 % UT(30 % dip in

during power mains interruptions, it

power supply

UT)for 25 cycles

 

 

UT) for 25 cycles

 

is recommended that the device be

input lines

<5 % UT(>95 % dip in

<5 % UT(>95 % dip in

powered from an

uninterruptible

IEC61000-4-11

UT)for 5 sec

 

 

UT) for 5 sec

 

power supply or a battery.

 

 

 

 

 

 

 

 

 

Power frequency

 

 

 

 

 

 

Power frequency

magnetic fields

(50/60Hz)

 

3 A/m

 

 

3 A/m

 

should be at levels characteristic of

 

magnetic field

 

 

 

 

atypical location in a typical

 

 

 

 

 

 

 

 

IEC61000-4-8

 

 

 

 

 

 

commercial or hospital environment.

 

 

 

 

 

 

 

 

 

 

 

NOTE: UT is the a.c. mains voltage prior to the application of the test level

765000-INS-LAB-RevB10

21

Image 21
Contents 765000 Contents Intended USE of this Device IntroductionImportant Safety Precautions INS-LAB-RevB10 INS-LAB-RevB10 Equipment Symbols Pump and Mattress System Product DescriptionPump Front Pump RearFront panel, first row Pump Front PanelFront panel, second row Front panel, third row Power failure. Depress the alarm mute button to disable Installation Pump and Mattress SetupUnpacking INS-LAB-RevB10 Operation Getting StartedQuick Disconnect CPR Function Transport CAPMaintenance CleaningGeneral Maintenance Fuse replacement Air filter replacement Storage Pump Specification SpecificationsLimited Warranty Appendix a EMC Information INS-LAB-RevB10 =1.2 P = 2.3 P GF Health Products, Inc
Related manuals
Manual 24 pages 11.97 Kb