Philips 861304 owner manual Treating infants and children, If a shock is not needed

Page 18
I-button

10

i-button flashes.

If a shock is not needed:

The blue i-button comes on solid, to show that it is safe to touch the patient. The FRx also tells you to perform CPR if needed. (If CPR is not needed – for example, if the patient is moving or regaining consciousness – follow your local protocol until emergency medical personnel arrive.) Then the FRx invites you to press the flashing blue i-button for CPR Coaching if desired.

For CPR Coaching:

Press the flashing blue i-button during the first 30 seconds of the patient care pause to activate CPR Coaching.*

(If the Infant/Child Key is inserted, the CPR Coaching provided will be for infant/child CPR.) When the pause is

over, the defibrillator tells you to stop CPR, so it can analyze the patient’s heart rhythm. The motion caused by CPR can interfere with analysis, so be sure to stop all motion when instructed.

Treating infants and children

WARNING: Most cardiac arrests in children are not caused by heart problems. When responding to cardiac arrest in an infant or child:

Provide infant/child CPR while a bystander calls EMS and brings the FRx.

If no bystander is available, provide 1-2 minutes of CPR before calling EMS and retrieving the FRx.

If you witnessed the child's collapse, call EMS immediately and then get the FRx.

Alternatively, follow your local protocol.

*The default configuration for the FRx provides CPR Coaching when you press the i-button in this situation; however, the default setting can be revised by your Medical Director using Philips software available separately. See Appendix F for more information.

Philips Medical Systems

HEARTSTART FRx 861304 OWNER’S MANUAL

Image 18
Contents 861304 N E R ’ S M a N U a LEdition Philips Medical Systems Quick Reference Intentionally blank HeartStart FRx Authorized EU Representative About This Edition Edition HistoryCopyright Device TrackingContents Appendices Description Sudden Cardiac ArrestIndications for Use Training and practiceState and local requirements Package contents For more informationSetting up the FRx 1A. Remove Pads Case from packagingPhilips Medical Systems Recommended accessories Using the HeartStart FRx OverviewPress the green on/off button Follow the FRx’s voice instructionsOpen the pads case as shown below. Peel off one pad Press the flashing orange Shock button if instructed If a shock is neededTreating infants and children If a shock is not neededKey if available When emergency medical services arrive Infant/Child KeyPhilips Medical Systems After using the HeartStart FRx After each useFRx data storage Routine maintenance Maintaining the HeartStart FRxCleaning the FRx Periodic checksDisposing of the FRx Troubleshooting tips Appendices Philips Medical Systems Accessories Appendices Glossary of terms Infant/Child Key HeartStart Event ReviewButton Coaching, if selected, appropriate for infants and childrenOn/Off button When a battery is insertedPatient care in the AED mode Pads See Smart PadsConsciousness, absence of respiration, and lack of a pulse Standby modeBlinking green Ready light Waveform See Smart biphasic waveformGlossary of symbols/controls Standby mode gives device statusShock is advised, as a reminder not to touch the patient Symbol  #  Appendices Hazard. Do not sterilize the FRx or its accessories Please read these warnings and precautions carefullyApproved accessories are used AccessoriesPrecautions Physical HeartStart FRx 861304 Defibrillator specificationsTechnical information EnvironmentalControls and indicators Category Specifications SealingProtected Defibrillation waveform Current aEnergy dose Disarm AED mode Adult shock delivery vectorCategory Energy Charge control Shock-to-shock cycle time Newborn 14 J/kgECG analysis system ECG analysis performanceRhythm class Samplea size Performance Lower Accessories specifications HeartStart Smart Pads IIM5070A battery and 989803139301 TSO C-142* battery Category Battery type CapacityInfant/Child Key Environmental considerations EnvironmentRegulations Configuration Overview Device optionsPatient treatment protocol options Background monitoring. If a NSA pause type SettingsDefibrillator conducts Is detected in a motionlessCPR reminder voice CPR prompt SettingsCPR1 Instructs the user to begin CPR Instructs Instructions provided at User that it isPads set is installed When an adult pads set isInstalled CPR Coaching infant/child ventilation instructionTroubleshooting Testing and troubleshootingTesting Recommended action when you need to use the deviceTo replace pads Troubleshooting while the FRx is being usedDefibrillator says To make sure the pads have been removed from the caseDefibrillator says To stop all motion Troubleshooting while the FRx is not being used BehaviorElectromagnetic emissions Additional technical data required for European conformityElectromagnetic conformity Emissions testElectromagnetic immunity MHz to2.5 GHz Rated maximum output power of transmitter W 100Separation distance according to frequency of transmitter m = 1.15√ PAppendices Philips Medical Systems Intentionally blank Europe, Middle East, and Africa Philips Medical Systems United StatesCanada Latin America

861304 specifications

The Philips 861304 is a versatile and advanced home appliance that blends functionality with sleek design, making it an ideal choice for modern households. This innovative product is particularly known for its impressive performance in the realm of kitchen technology.

One of the standout features of the Philips 861304 is its state-of-the-art cooking capabilities. Equipped with an advanced heating system, the appliance ensures even and precise cooking temperatures. The user can enjoy a variety of cooking modes, including steaming, baking, and grilling, which allow for diverse culinary experiments. This versatility is complemented by a robust set of presets that simplify meal preparation, making it accessible for even novice cooks.

In terms of technology, the Philips 861304 utilizes innovative Rapid Air Technology that circulates hot air around the food. This not only ensures even cooking but also enhances the flavor while reducing the need for excess oil, making meals healthier. The appliance also features an intuitive touch-screen interface, allowing users to select their desired cooking settings with ease. This user-friendly design is critical for those who are busy but still want to enjoy home-cooked meals without the stress of complicated controls.

Another key characteristic of the Philips 861304 is its commitment to safety. The appliance is equipped with multiple safety features, including an automatic shut-off function and cool-touch handles, ensuring peace of mind during operation. Its compact design makes it suitable for kitchens of all sizes, allowing users to enjoy high-end cooking technology without sacrificing counter space.

The Philips 861304 is also designed with cleanliness in mind. The non-stick surface ensures easy food release and simplifies the cleaning process. Many components are dishwasher-safe, further streamlining maintenance and promoting a hygienic cooking environment.

In summary, the Philips 861304 stands out in the crowded market of kitchen appliances due to its advanced heating technology, user-friendly interface, and commitment to safety and cleanliness. Its combination of versatility and performance makes it a valuable addition to any culinary space, empowering users to effortlessly create delicious and healthy meals.