Philips Medical Systems

15

FRx data storage

The FRx automatically stores data about its last clinical use in its internal memory. The stored data can be conveniently transferred to a personal computer or a handheld computer running the appropriate application in the Philips HeartStart Event Review data management software suite. Event Review software is for use by trained personnel only. Information about HeartStart Event Review is available online www.medical.philips.com/goto/eventreview.

Follow your local protocol with regard to prompt data transfer for medical review after using the FRx.* Details about data transfer and timing are provided in Event Review documentation.

The information automatically stored by the FRx includes a summary of last-use data and detailed data about its last clinical use. You can get a voice summary of information about the last use of the defibrillator by holding the i-button down until it beeps once. The FRx will tell you how many shocks were delivered and how long it has been since it was turned on. Summary data are available anytime the defibrillator is ready for use (the battery and pads are installed, and the defibrillator is not turned on) or while it is actually in use. Removing the battery erases the summary data for the last use.

Last-use data stored in internal memory include:

ECG recordings (a maximum of 15 minutes following pads application)

*The FRx automatically stores information about its last clinical use in its internal memory for at least 30 days, so the data can be downloaded to a computer running appropriate Event Review software. (If the battery is removed during this period, the defibrillator retains the files. When the battery is reinstalled, the last-use ECG recording will be kept in defibrillator memory for an additional 30 days.) After this time, the last-use ECG recordings will automatically be

erased to prepare for a future use.

If ECG recordings from a previous use have not been erased, the maximum time for new ECG recordings may be less.

Image 23
Contents Edition 861304N E R ’ S M a N U a L Philips Medical Systems Quick Reference Intentionally blank HeartStart FRx Device Tracking About This Edition Edition HistoryCopyright Authorized EU RepresentativeContents Appendices Sudden Cardiac Arrest DescriptionState and local requirements Indications for UseTraining and practice For more information Package contents1A. Remove Pads Case from packaging Setting up the FRxPhilips Medical Systems Recommended accessories Overview Using the HeartStart FRxOpen the pads case as shown below. Peel off one pad Press the green on/off buttonFollow the FRx’s voice instructions If a shock is needed Press the flashing orange Shock button if instructedIf a shock is not needed Treating infants and childrenKey if available Infant/Child Key When emergency medical services arrivePhilips Medical Systems After each use After using the HeartStart FRxFRx data storage Maintaining the HeartStart FRx Routine maintenanceDisposing of the FRx Cleaning the FRxPeriodic checks Troubleshooting tips Appendices Philips Medical Systems Accessories Appendices Glossary of terms Coaching, if selected, appropriate for infants and children HeartStart Event ReviewButton Infant/Child KeyPads See Smart Pads When a battery is insertedPatient care in the AED mode On/Off buttonWaveform See Smart biphasic waveform Standby modeBlinking green Ready light Consciousness, absence of respiration, and lack of a pulseShock is advised, as a reminder not to touch the patient Glossary of symbols/controlsStandby mode gives device status Symbol  #  Appendices Accessories Please read these warnings and precautions carefullyApproved accessories are used Hazard. Do not sterilize the FRx or its accessoriesPrecautions Environmental HeartStart FRx 861304 Defibrillator specificationsTechnical information PhysicalProtected Controls and indicatorsCategory Specifications Sealing Current a Defibrillation waveformNewborn 14 J/kg Disarm AED mode Adult shock delivery vectorCategory Energy Charge control Shock-to-shock cycle time Energy doseRhythm class Samplea size Performance Lower ECG analysis systemECG analysis performance HeartStart Smart Pads II Accessories specificationsInfant/Child Key M5070A battery and 989803139301 TSO C-142* batteryCategory Battery type Capacity Regulations Environmental considerationsEnvironment Overview Device options ConfigurationPatient treatment protocol options Is detected in a motionless NSA pause type SettingsDefibrillator conducts Background monitoring. If aInstructs Instructions provided at User that it is CPR prompt SettingsCPR1 Instructs the user to begin CPR CPR reminder voiceCPR Coaching infant/child ventilation instruction When an adult pads set isInstalled Pads set is installedRecommended action when you need to use the device Testing and troubleshootingTesting TroubleshootingTo make sure the pads have been removed from the case Troubleshooting while the FRx is being usedDefibrillator says To replace padsDefibrillator says To stop all motion Behavior Troubleshooting while the FRx is not being usedEmissions test Additional technical data required for European conformityElectromagnetic conformity Electromagnetic emissionsElectromagnetic immunity = 1.15√ P Rated maximum output power of transmitter W 100Separation distance according to frequency of transmitter m MHz to2.5 GHzAppendices Philips Medical Systems Intentionally blank Latin America Philips Medical Systems United StatesCanada Europe, Middle East, and Africa

861304 specifications

The Philips 861304 is a versatile and advanced home appliance that blends functionality with sleek design, making it an ideal choice for modern households. This innovative product is particularly known for its impressive performance in the realm of kitchen technology.

One of the standout features of the Philips 861304 is its state-of-the-art cooking capabilities. Equipped with an advanced heating system, the appliance ensures even and precise cooking temperatures. The user can enjoy a variety of cooking modes, including steaming, baking, and grilling, which allow for diverse culinary experiments. This versatility is complemented by a robust set of presets that simplify meal preparation, making it accessible for even novice cooks.

In terms of technology, the Philips 861304 utilizes innovative Rapid Air Technology that circulates hot air around the food. This not only ensures even cooking but also enhances the flavor while reducing the need for excess oil, making meals healthier. The appliance also features an intuitive touch-screen interface, allowing users to select their desired cooking settings with ease. This user-friendly design is critical for those who are busy but still want to enjoy home-cooked meals without the stress of complicated controls.

Another key characteristic of the Philips 861304 is its commitment to safety. The appliance is equipped with multiple safety features, including an automatic shut-off function and cool-touch handles, ensuring peace of mind during operation. Its compact design makes it suitable for kitchens of all sizes, allowing users to enjoy high-end cooking technology without sacrificing counter space.

The Philips 861304 is also designed with cleanliness in mind. The non-stick surface ensures easy food release and simplifies the cleaning process. Many components are dishwasher-safe, further streamlining maintenance and promoting a hygienic cooking environment.

In summary, the Philips 861304 stands out in the crowded market of kitchen appliances due to its advanced heating technology, user-friendly interface, and commitment to safety and cleanliness. Its combination of versatility and performance makes it a valuable addition to any culinary space, empowering users to effortlessly create delicious and healthy meals.