Bushnell 1000 manual Example, What if your caliber is not listed?

Page 11

Above are a few of the most popular caliber / load combinations. The enclosed Ballistics CD contains approximately 1000 caliber and load combinations. Simply load the CD into your computer CD drive and follow the instructions on your screen. This complete list can also be found on Bushnell’s website (www.bushnell.com).

After you have determined which ballistic group corresponds to your caliber and load, select this ballistic group (See MENU SETUP above).

The internal formula will determine amount of bullet drop / holdover in inches or centimeters based upon distance, angle, and ballistics of your caliber and load.

NOTE: All bullet drop / holdover data for ballistic settings A, B, C, D, E, F, G, and H assumes the rifle has been sighted in at 100 yards. Bullet drop / holdover date for ballistic setting I and J assume the muzzleloader has been sighted in at 150 yards.

This state-of-the-art digital technology allows the hunter or shooter to know precisely where to hold for an effective shot. This information should be treated as a helpful guide or tool and in no way should it ever replace practice and familiarity with your rifle, cartridge and load. We encourage practice shooting at different ranges so you know how your rifle, cartridge and load will perform under various conditions. Always know what is behind your bullet; if you don’t know, don’t take the shot.

EXAMPLE

You have a 300 WSM and are shooting the following Winchester brand load: 180 gr. Ballistic Silver Tip bullet at 3010 FPS muzzle velocity. This combination falls under Ballistic Group “F”. After setting the rangefinder to ballistic group “F”, go to the range and sight in your riflescope at 100 yards. If you then take a shot at a target at 317 yds, the bullet drop will be 9 inches. If the shot is at angle of 27 degrees upward, then the corrected bullet drop will be 8 inches.

What if your caliber is not listed?

While we have taken great care to include as many calibers and brand names in our ballistics tables, new loads are always being developed. In addition, some shooters load their own ammunition with unique ballistic characteristics. If you cannot find your load in our ballistic tables, you can still use the bullet drop feature of the laser rangefinder. As above, sight in your rifle at 100 yds. Then shoot the rifle, without adjusting the riflescope, at 300 yds. Measure the bullet drop from the point of aim. Using this drop, select the ballistic group from below. If you will be shooting longer distances then you may want to check the bullet drop at 500 yds. Because there is enormous variation in rifle barrels, chambers, and hand loads, you should thoroughly test the ballistic setting before actual hunting. You may need to move up or down one group depending upon your tests.

If Bullet Drop is:

@300 yds

@300 m

@500 yds

@500 m

 

 

 

 

 

Use:

 

 

 

 

 

 

 

 

 

A

25-31 inches

63-79 cm

114-146 inches

291-370 cm

 

 

 

 

 

B

20-25 inches

50-63 cm

88-114 inches

225-291 cm

 

 

 

 

 

C

16-20 inches

40-50 cm

72-88 inches

182-225 cm

 

 

 

 

 

D

13-16 inches

34-40 cm

61-72 inches

155-182 cm

 

 

 

 

 

E

12-13 inches

30-34 cm

55-61 inches

139-155 cm

 

 

 

 

 

F

10-12 inches

25-30 cm

47-55 inches

119-139 cm

G

8-10 inches

20-25 cm

39-47 inches

99-119 cm

H

Less than 8 inches

Less than 20 cm

Less than 39 inches

Less than 99 cm

20

21

Image 11
Contents Scout 1000 Scout Power Eyepiece Mode Tripod Mount Ranging Accuracy HOW OUR Digital Technology WorksOperational Summary Getting Started Inserting the BatteryAdjusting the Eyepiece Liquid Crystal Display LCD IndicatorsSelective Targeting Modes Unit of Measure OptionsActive Laser Page Tripod Mount Magnification and CoatingsPage Rifle Mode Example BOW Mode ExampleKnowing Which Ballistic Group to Select Regular ModeWhat if your caliber is not listed? ExampleCleaning SpecificationsIf target range cannot be obtained If unit does not turn on LCD does not illuminateScout 1000 Scout MARCHE/ARRÊT alimentation Oculaire Mode Monture de trépied Précision EN Distance Comment Notre Technologie FonctionneIndicateurs DE L’AFFICHAGE À Cristaux Liquides LCD Comment Démarrer Mise EN Place DE LA PileRéglage DE L’OCULAIRE Fonctionnement EN BrefLaser Activé Mode DE Visée SélectiveOptions D’UNITÉ DE Mesure Page Monture DE Trépied Grossissement et traitementsNormal clignote au bas de l’écran Exemple DU Mode Fusil Exemple DU Mode TIR À L’ARCSavoir Quel Groupe Balistique Sélectionner Mode NormalEt si le calibre n’est pas sur la liste ? ExempleNettoyage CaractéristiquesSi la distance de la cible ne peut pas être obtenue Si l’appareil ne s’allume pas l’écran LCD ne s’active pasEspañol ON/OFF Encendido Ocular Modalidad Montura de trípode Exactitud DE LA Telemetría Cómo Funciona Nuestra Tecnología DigitalIndicadores DE LA Pantalla DE Cristal Líquido LCD Instrucciones Iniciales Cómo Introducir LA PilaCómo Ajustar EL Ocular Resumen OperacionalModalidades Selective Targeting Opciones DE Unidad DE MedidaLáser Activo Figura Adaptador DE Montaje EN Trípode Aumentos y recubrimientosUnidad DE Medida Ejemplo DE Modalidad Rifle Ejemplo DE Modalidad BOW ArcoCómo Saber QUÉ Grupo Balístico Seleccionar Modalidad Regular¿Qué hacer si su calibre no aparece en la lista? EjemploLimpieza EspecificacionesSi no se puede obtener la distancia al blanco Si la unidad no se enciende La pantalla LCD no se enciendeDeutsch AN/AUS Stromversorgung Ovular Modus Stativmontage Genauigkeit DER Entfernungsmessung Funktionsweise Unserer DigitaltechnologieZusammenfassung DER Funktionsweise LCD-ANZEIGEN Inbetriebnahme Einsetzen DER BatterieEinstellen DES Okulars Selektive Targeting Modi MESSEINHEITS-OPTIONENAktiver Laser Page Stativmontage Vergrößerung und VergütungPage Beispiel GEWEHR-MODUS Beispiel BOGEN-MODUSDIE Wahl DER Richtigen Ballistischen Gruppe Normaler ModusIhr Kaliber ist nicht aufgeführt. Was nun? BeispielReinigung Technische DatenDie Zielentfernung lässt sich nicht feststellen 101102 104 Descrizione Della Tecnologia Digitale Impiegata 105106 Regolazione DELL’OCULARE Indicatori SUL Display a Cristalli Liquidi LCD108 PER Iniziare Inserimento Della PilaModalità Selective Targeting 110Indicazione DELL’UNITÀ DI Misura Laser Attivoi112 Sostegno PER Treppiede 113114 Ingrandimento e trattamentoAcceso ed il messaggio lampeggerà sul display, in basso 116118 Esempio DI Modo Arco117 Esempio DI Modo Fucile120 Come Selezionare IL Gruppo Balistico Appropriato122 121Pulizia 124Dati Tecnici Se non si riesce a misurare la distanza dal bersaglio 126Se l’unità non si accende il LED non si illumina 127 129 Como Funciona Nossa Tecnologia Digital 131Resumo Operacional 133Como Começar Inserção DA Pilha Ajuste DA OcularModos Selective Targeting 135Opções DA Unidade DE Medida Laser AtivoFigura 137Montagem EM Tripé 138139 Ampliação e revestimentos141 Menu de Configuração Menu de operação normal143 Exemplo do Modo ArcoExemplo do Modo Rifle 145 Seleção do Grupo DE Balística Apropriado147 146Limpeza 149Especificações Se a leitura da distância do alvo não puder ser obtida 151Unidade não liga o LCD não acende